-
- Maayan Konigstein, Eyal Ben-Assa, Yigal Abramowitz, Arie Steinvil, Eran Leshem Rubinow, Ofer Havakuk, Yaron Arbel, Amir Halkin, Gad Keren, Shmuel Banai, and Ariel Finkelstein.
- Department of Cardiology, Tel Aviv Medical Center, Tel Aviv, Israel; The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
- Am. J. Cardiol. 2013 Dec 1; 112 (11): 1807-11.
AbstractAcute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI) is frequent and associated with adverse outcomes. We aimed to identify the incidence and risk factors for AKI after TAVI using the updated Valve Academic Research Consortium-2 classification criteria. We performed a retrospective analysis of 300 consecutive patients undergoing TAVI using either Edwards SAPIEN XT or CoreValve bioprostheses at our medical center. Change in serum creatinine from base line to 48 to 72 hours after TAVI was used to define AKI stages 1 to 3. The final study cohort included 251 patients. Overall incidence of AKI was 16.7% (42 of 251); of which, stage 1 AKI was 15.1% (38 of 251), stage 2 AKI was 1.6% (4 of 251), and none had stage 3 AKI or required hemodialysis. All-cause mortality at 30 days and 1 year was greater among patients with AKI (9.5% vs 1%, p <0.01% and 25.7% vs 12.3%, p = 0.041, respectively). Despite greater volume of contrast media used in Edwards SAPIEN versus CoreValve (162 ml vs 142 ml, p = 0.02), there was no difference in the incidence of AKI between the 2 valve types (23.7% vs 15.5%, p = 0.238) or when comparing larger (29 to 31 mm) versus smaller size valves (23 to 26 mm; 17.7% vs 16.1%, p = 0.745). AKI was associated with chronic kidney disease, history of peripheral vascular disease, blood transfusion, and higher EuroSCORE (p <0.05 for all). In conclusion, according to the new Valve Academic Research Consortium-2 classification, 1 in every 6 patients in our cohort developed AKI after TAVI (most were stage 1 AKI). AKI was associated with increased mortality. No difference in AKI incidence was observed between different types and sizes of bioprostheses used.Copyright © 2013 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.