    Comparative Study

    Evaluation of neonatal membrane oxygenators with respect to gaseous microemboli capture and transmembrane pressure gradients.

    • Feng Qiu, Yulong Guan, Xiaowei Su, Allen Kunselman, and Akif Undar.
    • Department of Pediatrics and Surgery, Penn State Hershey Pediatric Cardiovascular Research Center, PA, USA.
    • Artif Organs. 2010 Nov 1; 34 (11): 923-9.

    AbstractA series of studies performed at our center demonstrates that gaseous microemboli (GME) remain a challenge in cardiac surgical procedures. Evaluation of novel oxygenators must address hemodynamic parameters and microemboli capture capability. The objective of this study is to compare two neonatal membrane oxygenators, the Quadrox-i (MAQUET Cardiopulmonary AG, Hirrlingen, Germany) and the Capiox RX05 (Terumo Corporation, Tokyo, Japan), with respect to GME capture and hemodynamic energy delivery. The experimental circuit included a Maquet HL-20 heart-lung machine, a Heater-Cooler Unit HCU 30 (MAQUET Cardiopulmonary AG), a membrane oxygenator (Quadrox-i Neonatal or Capiox RX05), and ¼-inch tubing from the COBE Heart/Lung Perfusion Pack (COBE Cardiovascular, Inc., Arvada, CO, USA). A Capiox cardiotomy reservoir CX*CR10NX (Terumo Corporation) acted as a pseudopatient. The circuit was primed with human packed red blood cells and lactated Ringer's solution and de-aired according to clinical priming procedure. Heparin (5000IU) was added into the circuit. The total volume was 400mL and hematocrit was 30%. Pump flow rate was maintained at 500 or 1000mL/min under both pulsatile and nonpulsatile modes. All trials were conducted under 100mm Hg of circuit pressure at normothermia (35°C). In each trial, bolus air (0.5mL) was injected into the circuit at the prepump site over 5s. Total emboli counts and total emboli volume were significantly reduced by the Quadrox-i Neonatal membrane oxygenator compared to the Capiox RX05 membrane oxygenator. Classification and quantification of GME detected at the postoxygenator site at two different flow rates indicated that the Quadrox-i Neonatal captures the majority of microemboli larger than 40µm in diameter. The Quadrox-i Neonatal membrane oxygenator had a higher transmembrane pressure drop at 500mL/min, whereas it had a lower pressure drop at 1000mL/min compared to the Capiox Baby RX05 oxygenator. Additionally, the Quadrox-i Neonatal oxygenator preserved more pulsatile energy than the Baby RX05 oxygenator at both flow rates. Compared to the Capiox RX05 membrane oxygenator, the Quadrox-i Neonatal membrane oxygenator has significantly improved GME handling capacity and had better hemodynamic energy preservation. Further research encompassing in vivo and clinical studies is needed to investigate the magnitude and mechanisms of these benefits.© 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.