• Conf Proc IEEE Eng Med Biol Soc · Jan 2004

    A comprehensive physiological model of circulation enables automatic piloting of hemodynamics in patients with acute heart failure.

    • M Sugimachi, K Uemura, T Kawada, M Inagaki, and K Sunagawa.
    • Department of Cardiovascular Dynamics, National Cardiovascular Center Research Institute, Osaka, Japan.
    • Conf Proc IEEE Eng Med Biol Soc. 2004 Jan 1; 5: 3716-9.

    AbstractA comprehensive physiological model of the whole circulation is mandatory to quantitatively diagnose pathophysiology and to guide an appropriate treatment. Such a model would enable automatic piloting of hemodynamics in patients with acute heart failure. By extending Guyton's model, so as to deal with heart failure predominantly affecting left heart and to quantify left atrial pressure, we constructed such a model consisting of a venous return (VR) surface and a cardiac output (CO) curve. VR surface, the integrated property of systemic and pulmonary vascular beds, relates VR and left and right atrial pressures (P(LA), P(RA)) linearly as VR = V/W - G(R)P(RA) - G(L)P(LA), given total blood volume (V). CO curve, the pumping ability of hearts, relates CO and either P(LA) or P(RA) approximately by logarithmic functions, respectively, as CO = S(L) [ln (P(LA)- B(L)) + C(L)] = S(R) [ln (P(RA) - B(R)) + C(R)]. The slopes (S(R) and S(L)) of CO curve mainly describes the pump performance. W, G(R), G(L), B(R), B(L), C(R) and C(L) are parameters. We validate the model with animal experiments. Parameters W, G's, B's and C's were relatively constant in 19 dogs. In other 8 dogs, with or without acute left heart failure, we determined V and S's from a single set of CO, P(RA), P(LA) and standard parameter values. We then predicted hemodynamics (CO, P(RA), P(LA)) for altered V from -8 to +8 ml/kg. We identified standard values of parameters as W (0.13 min), G(R) (19.6 ml/min/kg/mmHg), G(L) (3.5 ml/min/kg/mmHg). B(L) (2.1 mmHg), C(L) (1.9), B(R) (2.0 mmHg) and C(R) (0.80). Using these, we could accurately predict CO (y = 0.93x + 6.5, r2 = 0.96, Figure 2), P(RA) (y = 0.87x + 0.4, r2 = 0.91) and P(LA) (y = 0.90x + 0.48, r2 = 0.93). Our comprehensive physiological model of circulation is useful in accurately predicting hemodynamics from the measurement of a single set of CO, P(RA) and (P(LA) following blood volume changes. Therefore, this model enables continuous monitoring of blood volume and pump performance for automatic hemodynamic piloting.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…