• J Orthop Trauma · Dec 2013

    Comparative Study

    The effect of fracture pattern stability on implant loading in OTA type 31-A2 proximal femur fractures.

    • Meir Marmor, Kate Liddle, Murat Pekmezci, Jenni Buckley, and Amir Matityahu.
    • *Orthopaedic Trauma Institute, San Francisco General Hospital, University of California-San Francisco, San Francisco, CA; and †The Taylor Collaboration, San Francisco, CA.
    • J Orthop Trauma. 2013 Dec 1; 27 (12): 683-9.

    BackgroundInternal fixation of OTA type 31-A2 proximal femoral fractures can be performed with either a sliding hip screw and side plate (SHS-P) or a sliding hip screw and intramedullary nail (SHS-IMN). Controversy exists as to which is the best implant for these types of fractures. The primary aim of this study was to investigate the stability of 31-A2 fractures as a function of loss of medial cortical buttress. The secondary aim was to assess the influence of fracture stability on the different internal fixation constructs.MethodsSimulated simple intertrochanteric fractures were made in 12 cadaver proximal femurs. Six fractures were fixed with an SHS-P and 6 with an SHS-IMN. Both implants were instrumented with a strain gauge at the lag screw-nail/plate interface to allow assessment of implant load bearing (ILB). A primary fracture line, in accordance with the 31-A2 OTA classification, was created after which 3 subsequent horizontal osteotomies in 1-cm increments were made across the medial cortex. Compressive loading up to 1050 N was performed after each osteotomy.ResultsILB was presented as percentage of maximal ILB. SHS-P constructs increased their load bearing gradually. For SHS-P constructs, ILB was 8.1% ± 1.8% in the intact state, increasing to 49.6% ± 14.0% after the initial intertrochanteric osteotomy (P = 0.0002), 68.7% ± 15.9% after the first medial osteotomy (P = 0.028), and 80.0% ± 15.9% after the second medial osteotomy (P = 0.15). After the first-level medial osteotomy, SHS-IMN constructs reached a plateau in which the implant carried the entire load.ConclusionsType 31-A2 fractures become increasingly unstable with increased medial comminution (or fragment size). SHS-P constructs were more load sharing than SHS-IMN constructs. These findings may help guide the surgeon in choice of implant for a 31-A2 intertrochanteric fracture, leaning toward SHS-IMN for the more unstable fracture patterns.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.