• Cochrane Db Syst Rev · Mar 2016

    Review Meta Analysis

    Perioperative fluid volume optimization following proximal femoral fracture.

    • Sharon R Lewis, Andrew R Butler, Andrew Brammar, Amanda Nicholson, and Andrew F Smith.
    • Patient Safety Research, Royal Lancaster Infirmary, Pointer Court 1, Ashton Road, Lancaster, UK, LA1 1RP.
    • Cochrane Db Syst Rev. 2016 Mar 14; 3 (3): CD003004CD003004.

    BackgroundProximal femoral fracture (PFF) is a common orthopaedic emergency that affects mainly elderly people at high risk of complications. Advanced methods for managing fluid therapy during treatment for PFF are available, but their role in reducing risk is unclear.ObjectivesTo compare the safety and effectiveness of the following methods of perioperative fluid optimization in adult participants undergoing surgical repair of hip fracture: advanced invasive haemodynamic monitoring, such as transoesophageal Doppler and pulse contour analysis; a protocol using standard measures, such as blood pressure, urine output and central venous pressure; and usual care.Comparisons of fluid types (e.g. crystalloid vs colloid) and other methods of optimizing oxygen delivery, such as blood product therapies and pharmacological treatment with inotropes and vasoactive drugs, are considered in other reviews.Search MethodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 9); MEDLINE (October 2012 to September 2015); and EMBASE (October 2012 to September 2015) without language restrictions. We ran forward and backward citation searches on identified trials. We searched ClinicalTrials.gov and the World Health Organization (WHO) International Clinical Trials Registry Platform for unpublished trials. This is an updated version of a review published originally in 2004 and updated first in 2013 and again in 2015. Original searches were performed in October 2003 and October 2012.Selection CriteriaWe included randomized controlled trials (RCTs) in adult participants undergoing surgical treatment for PFF that compared any two of advanced haemodynamic monitoring, protocols using standard measures or usual care, irrespective of blinding, language or publication status.Data Collection And AnalysisTwo review authors assessed the impact of fluid optimization interventions on outcomes of mortality, length of hospital stay, time to medical fitness, whether participants were able to return to pre-fracture accommodation at six months, participant mobility at six months and adverse events in-hospital. We pooled data using risk ratio (RR) or mean difference (MD) for dichotomous or continuous data, respectively, on the basis of random-effects models.Main ResultsWe included in this updated review five RCTs with a total of 403 participants, and we added two new trials identified during the 2015 search. One of the included studies was found to have a high risk of bias; no trial featured all pre-specified outcomes. We found two trials for which data are awaited for classification and one ongoing trial.Three studies compared advanced haemodynamic monitoring with a protocol using standard measures; three compared advanced haemodynamic monitoring with usual care; and one compared a protocol using standard measures with usual care. Meta-analyses for the two advanced haemodynamic monitoring comparisons are consistent with both increased and decreased risk of mortality (RR Mantel-Haenszel (M-H) random-effects 0.41, 95% confidence interval (CI) 0.14 to 1.20; 280 participants; RR M-H random-effects 0.45, 95% CI 0.07 to 2.95; 213 participants, respectively). The study comparing a protocol with usual care found no difference between groups for this outcome.Three studies comparing advanced haemodynamic monitoring with usual care reported data for length of stay and time to medical fitness. There was no statistically significant difference between groups for these outcomes in the two studies that we were able to combine (MD IV fixed 0.63, 95% CI -1.70 to 2.96); MD IV fixed 0.01, 95% CI -1.74 to 1.71, respectively) and no statistically significant difference in the third study. One study reported reduced time to medical fitness when comparing advanced haemodynamic monitoring with a protocol, and when comparing protocol monitoring with usual care.The number of participants with one or more complications showed no statistically significant differences in each of the two advanced haemodynamic monitoring comparisons (RR M-H random-effects 0.83, 95% CI 0.59 to 1.17; 280 participants; RR M-H random-effects 0.72, 95% CI 0.40 to 1.31; 173 participants, respectively), nor any differences in the protocol and usual care comparison.Only one study reported the number of participants able to return to normal accommodation after discharge with no statistically significant difference between groups.There were few studies with a small number of participants, and by using the GRADE (Grades of Recommendation, Assessment, Development and Evaluation Working Group) approach, we judged the quality of the outcome evidence as low. We had included one study with a high risk of bias, but upon applying GRADE, we downgraded the quality of this outcome evidence to very low.Authors' ConclusionsFive studies including a total of 403 participants provided no evidence that fluid optimization strategies improve outcomes for participants undergoing surgery for PFF. Further research powered to test some of these outcomes is ongoing.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…