• Investigative radiology · Nov 2008

    Diagnostic accuracy of cardiac 64-slice computed tomography in detecting atrial thrombi. Comparative study with transesophageal echocardiography and cardiac surgery.

    • Gudrun M Feuchtner, Wolfgang Dichtl, Johannes O Bonatti, Daniel Jodocy, Silvana Müller, Florian Hintringer, Johannes Gradl, Andrea Klauser, and Ricardo C Cury.
    • Clinical Department of Radiology II, Innsbruck Medical University, Innsbruck, Austria. Gudrun.Feuchtner@i-med.ac.at
    • Invest Radiol. 2008 Nov 1; 43 (11): 794-801.

    ObjectivesAtrial thrombi are a potential source for cerebral and peripheral emboli. Objective of this study was to evaluate the diagnostic accuracy of 64-slice cardiac computed tomography (CT) for detection of atrial thrombi in comparison with transesophageal echocardiography (TEE) and cardiac surgery.Material And MethodsSixty-four patients were examined with ECG-gated multidetector CT coronary or pulmonary vein angiography. All patients underwent TEE. Cardiac surgery was performed in 31 patients. The Hounsfield units (HU) of atrial lesions were measured.ResultsThe diagnostic accuracy of 64-slice CT for the detection of atrial thrombi was 77%: sensitivity 100% (9/9), specificity 73% (40/55), positive predictive value (PPV) 38% (9/24), and negative predictive value (NPV) 100% (40/40). All 15 false positive (FP) findings by CT were located in the left atrial appendage (LAA). Four characteristic imaging features suggesting incomplete filling of the LAA were noted in FP: "hypostatic layering," 5/15 (33%); "flow phenomenon," 9/15 (60%); "HU-run-off," 8/15 (53%); higher intralesional HU in FP when compared with thrombi (153.8 HU +/- 71 vs. 46.6 HU +/- 10; P < 0.0001). The diagnostic accuracy of CT in detecting atrial thrombi improved significantly (P = 0.03) to 86% after defining "typical filling defects" as "flow phenomenon/>180 HU" (sensitivity 100%; specificity 84%; PPV 50%; NPV 100%). On receiver operating curve (ROC) analysis, a threshold of 60.7 HU showed a specificity of 100% and a sensitivity of 86.7% to distinguish between FP and thrombi.ConclusionsCardiac ECG-gated 64-slice CT is accurate to exclude atrial thrombi, which can be applied eg, in patients before radiofrequency (RF) ablation. Left atrial appendage "filling defects" cause a high number of false positive findings, and there are radiologic features, which are helpful to differentiate them from true thrombi.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…