-
Randomized Controlled Trial
Radioaerosol Pulmonary Deposition Using Mesh and Jet Nebulizers During Noninvasive Ventilation in Healthy Subjects.
- Valdecir C Galindo-Filho, Maria Eveline Ramos, Catarina S F Rattes, Antônio K Barbosa, Daniella C Brandão, Simone Cristina S Brandão, James B Fink, and Armèle Dornelas de Andrade.
- Department of Physical Therapy, Universidade Federal de Pernambuco, Recife City, Pernambuco, Brazil. vcastorgalindo@yahoo.com.
- Respir Care. 2015 Sep 1; 60 (9): 1238-46.
BackgroundIn vivo deposition studies of aerosol administration during noninvasive ventilation (NIV) are scarce in the literature. The aim of this study was to compare radioaerosol pulmonary index and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) of radio-tagged aerosol administered using vibrating mesh nebulizers and conventional jet nebulizers during NIV.MethodsThis was a crossover clinical trial involving 10 healthy subjects (mean age of 33.7 ± 10.0 y) randomly assigned to both treatment arms of this study: group 1 (NIV + vibrating mesh nebulizer, n = 10) and group 2 (NIV + jet nebulizer, n = 10). All subjects inhaled 3 mL of technetium-99m diethylenetriaminepentaacetic acid (25 mCi) and 0.9% saline solution via vibrating mesh and jet nebulizers during NIV through a face mask secured with straps while receiving positive inspiratory and expiratory pressures of 12 and 5 cm H2O, respectively. Scintigraphy was performed to count radioaerosol particles deposited in the regions of interest to determine radioaerosol mass balance from the lungs, upper airways, stomach, nebulizer, ventilator circuit, inspiratory and expiratory filters, and mask as a percentage.ResultsVibrating mesh nebulizers deposited 972,013 ± 214,459 counts versus jet nebulizer with 386,025 ± 130,363 counts (P = .005). In a determination of mass balance, vibrating mesh nebulizers showed a higher deposition of inhaled radioaerosol compared with jet nebulizers (23.1 ± 5.8% vs 6.1 ± 2.5%, P = .005) and a higher proportion of radioaerosol deposited into the lungs (5.5 ± 0.9% versus 1.5 ± 0.6%, respectively, P = .005). The residual drug volume was lower with vibrating mesh nebulizers (5.1 ± 1.5%) compared with jet nebulizers (41.3 ± 4.2%, P = .005).ConclusionsDuring NIV in healthy subjects, vibrating mesh nebulizers delivered > 2-fold more radiolabeled drug into the respiratory tract compared with conventional jet nebulizers. Additional studies are recommended in subjects with asthma, COPD, bronchiectasis, and cystic fibrosis to better understand differences in both aerosol delivery and response. (ClinicalTrials.gov registration NCT01889524.).Copyright © 2015 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.