- C M Hoshino, M W Christian, R V O'Toole, and T T Manson.
- R Adams Cowley Shock Trauma Center, Department of Orthopaedics, University of Maryland Medical Center, 22 S. Greene Street, T3R59, Baltimore, MD 21201, USA.
- Injury. 2016 Aug 1; 47 (8): 1676-84.
BackgroundWe sought to compare the incidence of complications after fixation of displaced femoral neck fractures in young adults treated with fixed-angle devices versus multiple cancellous screws and a trochanteric lag screw (Pauwel screw).MethodsWe conducted a retrospective cohort study at a level I trauma centre. Sixty-two skeletally mature patients (age range, 16-60 years) with displaced femoral neck fractures were included in the study. Forty-seven were treated with a fixed-angle device (sliding hip plate with screw or helical blade) and 15 with multiple cancellous screws placed in a Pauwel configuration. The main outcome measure was postoperative complication of osteonecrosis or nonunion treated with a surgical procedure.ResultsSignificantly fewer failures occurred in the fixed-angle group (21%) than in the screws group (60%) (p=0.008). Osteonecrosis was rare in the fixed-angle group, occurring in 2% of cases versus 33% of cases in the screws group (p=0.002). Consistent with previous studies, good to excellent reductions were associated with a failure rate of 25% and fair to poor reductions were associated with a failure rate of 55% (p=0.07). The best-case scenario of a good to excellent reduction stabilised with a fixed-angle device yielded a success rate of 85%.ConclusionIn young patients with displaced high-energy femoral neck fractures, fixed-angle devices resulted in fewer treatment failures than did Pauwel screws.Copyright © 2016. Published by Elsevier Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.