• Rheumatology · Nov 2007

    Comparative Study

    Comparing morphometric X-ray absorptiometry and radiography in defining vertebral wedge fractures in patients with ankylosing spondylitis.

    • D Vosse, C Heijckmann, R Landewé, D van der Heijde, S van der Linden, and P Geusens.
    • Department of Internal Medicine, Division of Rheumatology University Hospital, PO Box 58006202 AZ Maastricht, The Netherlands. dvo@sint.azm.nl
    • Rheumatology (Oxford). 2007 Nov 1; 46 (11): 1667-71.

    ObjectiveTo compare the level of agreement of quantitative morphometry of the vertebrae on lateral views of the spine using conventional X-ray and using a dual X-ray absorptiometry device (DXA) in determining the degree of wedging of vertebrae in patients with ankylosing spondylitis (AS).MethodsThirty patients with AS underwent DXA to acquire single-energy morphometric X-ray absorptiometry (MXA) scans and conventional lateral radiography (MRX) of the thoracic and lumbar spine. Vertebral anterior and posterior heights were measured and the anterior/posterior (AP)-ratio was calculated. We analysed the level of agreement for vertebral wedging between MRX and MXA on the patient level and on the vertebral level, using average AP-ratios per patient, and per vertebra, as well as dichotomized AP-ratios (above or below cut-off levels that are commonly used to identify fractures).ResultsPer-patient analysis showed good agreement between both methods in the whole spine [intraclass correlation coefficient (ICC) = 0.64], as well as in the thoracic (ICC = 0.66) and lumbar spine (ICC = 0.62) separately. Analysis on individual vertebrae showed differences in agreement dependent on which part of the spine was measured. The ICC on all vertebrae was 0.71, 0.76 in the lumbar and 0.43 in the thoracic vertebrae. If AP-ratios were translated into fractures (yes vs no) using different cut off levels for a fracture (AP-ratios 0.75, 0.80 or 0.85) between-method agreement became fair to good (kappa 0.26-0.35 in the thoracic and 0.47-0.80 in the lumbar vertebrae). Differences in classifications were in both directions and in all vertebral fractures according to the Genant definition. In this study with a prevalence of 5% of vertebral fractures, the positive predicted value (PPV) was 39% and the negative predicted value (NPV) was 97%.ConclusionAlthough the agreement between MRX and MXA in measuring global vertebral wedging, expressed as (mean) AP-ratio, was good, the reliability of both measures to assess wedging at the vertebral level was highly variable, ranging from fair to very good agreement, dependent on the level. If fracture studies are performed with either of both the methods, the results of wedging at the individual vertebral level cannot be generalized to the other method, except for wedging <0.75 at the lumbar spine. However, as the NPV was high, DXA could be of clinical value to select patients for further evaluation by X-ray to assess vertebral fractures as a sign of bone failure.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.