• Pediatr Crit Care Me · Jul 2009

    Automated measurement of the lower inflection point in a pediatric lung model.

    • David A Turner, David Heitz, David Zurakowski, and John H Arnold.
    • Division of Critical Care Medicine, Children's Hospital Boston, Harvard Medical School, Boston, MA, USA. david.turner@duke.edu
    • Pediatr Crit Care Me. 2009 Jul 1; 10 (4): 511-6.

    ObjectiveTo determine which flow setting most accurately detects the lower inflection point (Pflex) using an automated constant flow method and varying endotracheal tube (ETT) sizes with and without an airleak in a pediatric lung model.DesignInterventional laboratory study.SettingChildren's hospital research center.InterventionsA pediatric lung model was created with Pflexs of the inspiratory pressure-volume (P-V) curve set at 5 and 10 cm H2O using the ASL 5000 Test Lung (IngMar Medical, Pittsburgh, PA). Three ETT sizes (3.0, 4.0, 5.0 mm) were tested with and without a 25% airleak. P-V curves were obtained using an automated constant flow method at ten different flow rates.Measurements And Main ResultsWithout an ETT airleak, the lowest flow of 0.5 L/min led to the most accurate determination of Pflex regardless of ETT size or set Pflex (p < 0.001). When a 25% leak was introduced, accuracy of measured Pflex depended on both ETT size (p < 0.001) and flow rate (p < 0.001). Optimum flow rates for Pflex determination were 0.5, 1.0, and 1.5 L/min at Pflex of 5 cm H2O, and 2.0, 3.5, and 4.5 L/min at 10 cm H2O for 3.0, 4.0, and 5.0 mm ETTs, respectively (p < 0.001).ConclusionsEstimation of Pflex can be achieved using automated P-V curves with ETTs appropriate for pediatric use, with and without an airleak. ETT size and flow rate affect the accuracy of these measurements when an airleak is present, and use of increased flow rates to create the automated P-V curves can reduce error. These data support the idea that a low-flow technique provides the most accurate determination of Pflex in pediatric patients without a leak around their ETT, whereas increased flows are needed to compensate when an ETT airleak is present.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…