• J Vasc Interv Radiol · Nov 2005

    Bench-top evaluation of air flow through a valved peelable introducer sheath.

    • Thomas M Vesely, Peter J Ness, and John E Hart.
    • Mallinckrodt Institute Radiology, Washington University School of Medicine, 510 South Kingshighway Boulevard, St. Louis, Missouri 63110, USA. tmvesely@aol.com
    • J Vasc Interv Radiol. 2005 Nov 1; 16 (11): 1517-22.

    PurposeAir embolism is a rare but potentially fatal complication that may occur during the insertion of a central venous catheter. A valved peelable introducer sheath was developed to reduce the likelihood of an air embolus. This study was performed to determine the rate of air flow through this valved introducer sheath under different conditions that may be encountered in a clinical setting.Materials And MethodsA 16-F-diameter valved peelable introducer sheath was used for all experiments. A bench-top testing system was constructed that consisted of a vacuum source, a mass flow meter, and a digital vacuum gauge. A coupling device with a pneumatic O-ring was used to seal and connect the distal end of the introducer sheath to the testing system. A vacuum of -5 mm Hg was applied to the sealed distal end of the sheath to simulate physiologic conditions. The rate of air flow through the valved sheath was measured under three different conditions; (i) valve open, (ii) valve closed, and (iii) valve open but with the sheath manually pinched. Thirty air flow measurements were performed for each of the three test conditions.ResultsWhen the valve was in the open position, the mean rate of air flow through the introducer sheath was 417.2 mL/sec (range, 415.5-419.7 mL/sec). When the valve was in the closed position, the mean rate of air flow was 0.004 mL/sec (range, 0.000-0.067 mL/sec). When the valve was open but the sheath was manually pinched, the mean rate of air flow through the sheath was 31.7 mL/sec (range, 23.0-38.8 mL/sec). During the 90 testing procedures, the mean vacuum was -5.10 mm Hg (range, -5.00 to -5.45 mm Hg).ConclusionsThis bench-top study revealed that a massive amount of air flowed through the open 16-F introducer sheath when it was subjected to a vacuum of -5 mm Hg, a situation that may occur under normal physiologic conditions. The rate of air flow could be decreased by aggressively pinching the sheath but the rate of air flow was still substantial. This study demonstrated that the addition of a sophisticated valve mechanism can essentially eliminate air flow through a peelable introducer sheath.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…