- K N DeCampos, S H Keshavjee, L Tremblay, T Yamashiro, and A S Slutsky.
- Department of Surgery, Toronto Hospital, Ontario, Canada.
- J. Appl. Physiol. 1996 May 1; 80 (5): 1835-40.
AbstractIsolated perfused lung systems are commonly used to assess lung function in experimental studies. Assessment of hemodynamics and gas-exchange function in these systems is limited by the availability of venous blood. This study describes and validates a rat lung perfusion circuit in which a double-lung block ventilated with a hypoxic gas mixture [inspired O2 fraction (FIO2) 0.04; inspired CO2 fraction 0.08; deoxygenator (Deoxy) block] is used to provide blood with blood gases that are similar to mixed venous values to perfuse a study lung (FIO2 0.21; left lung only). This allows extended assessment of hemodynamics and gas exchange. Fifty adult male Wistar rats (300-400 g) were used as double-lung donors. Twenty-five perfusions (of both Deoxy and study lungs) were performed in four protocols (groups 1-5; n = 5). In protocol 1 (group 1), we tested whether exposure to room air affects the gas composition of the blood in the system. We found that the gas composition of the venous reservoir blood was identical to that of the blood entering the study block. In protocol 2, the effect of perfusion time and perfusion flow rate on the stability of the system was assessed. Lungs were perfused at 4 and 12 ml/min (groups 2 and 3, respectively), and the procedure was discontinued if edema or a marked decline in hemodynamics or gas-exchange function was observed. Pulmonary function was excellent and remained stable for 3 (at 12 ml/min) and 5 h (at 4 ml/min). In protocol 3, we examined whether hypoxic ventilation in the Deoxy lungs affects the stability of the system. Despite the low FIO2 used in the Deoxy lungs, the mean pulmonary arterial pressure-to-blood flow relationships in the study and Deoxy lungs were similar. Finally, in protocol 4, perfusion of a damaged study lung did not impair the function of the system. We conclude that this model permits reliable assessment of pulmonary function in rats under controlled ventilation and perfusion conditions. The use of a Deoxy double-lung block simplifies the perfusion apparatus and eliminates the main cause of instability of other systems that use an anesthetized host animal to provide venous blood.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.