Comparative Study
Aortic valve area discrepancy by Gorlin equation and Doppler echocardiography continuity equation: relationship to flow in patients with valvular aortic stenosis.
- I G Burwash, A Dickinson, R J Teskey, J W Tam, and K L Chan.
- Department of Medicine, Victoria General Hospital, Dalhousie University, Halifax, Canada. iburwash@ottawaheart.ca
- Can J Cardiol. 2000 Aug 1; 16 (8): 985-92.
BackgroundIn vitro studies have shown a discrepancy between aortic valve area (AVA) measurements derived invasively by Gorlin equation (Gorlin AVA) and noninvasively by Doppler echocardiography (Doppler-echo) continuity equation (Doppler AVA) during low flow states.ObjectiveTo assess whether a flow-related discrepancy between Gorlin AVA and Doppler AVA occurs in the clinical setting in patients with isolated valvular aortic stenosis.Patients And MethodsSeventy-five consecutive patients with isolated valvular aortic stenosis, who had AVA determined both invasively by Gorlin equation and noninvasively by Doppler-echo continuity equation, were retrospectively reviewed.ResultsGorlin AVA and Doppler AVA correlated (r=0.68) over the narrow AVA range (Gorlin AVA 0.30 to 1.22 cm2); however, Doppler AVA was systematically larger than Gorlin AVA (0.80+/-0.21 versus 0.70+/-0.23 cm2, AVA difference = 0.10+/-0.17 cm2, P<0.0001). The AVA difference was inversely related to invasive cardiac index (r=-0.51) and was significantly greater at low flow states (cardiac index less than 2.5 L/min/m2) than at normal flow states (cardiac index 2.5 L/min/m2 or more) (0.16+/-0.15 versus -0.03+/-0.15 cm2, P<0.0001). Independent predictors of the AVA difference were the difference between Doppler-echo and invasive cardiac output (P<0.0001); the difference between Doppler-echo and invasive mean transvalvular pressure gradient (P=0.0002); and the average cardiac output (Doppler-echo plus invasive cardiac output/2, P=0.001) at the time of the hemodynamic assessments. The AVA difference was not related to average pressure gradient, average AVA or patient characteristics.ConclusionsA flow-related discrepancy between Gorlin AVA and Doppler AVA occurs in the clinical setting of patients with isolated valvular aortic stenosis. This discrepancy should be considered when assessing aortic stenosis severity during low flow states, where Gorlin AVA may be significantly smaller than Doppler AVA.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.