• Der Anaesthesist · Aug 2009

    Comparative Study

    [Intensive care patients. Determining daily energy expenditure - a comparison of two methods].

    • K Rokuss, A Kalenka, H-J Bender, and J Hinkelbein.
    • Klinik für Anästhesiologie und Operative Intensivmedizin, Universitätsmedizin Mannheim, Mannheim.
    • Anaesthesist. 2009 Aug 1; 58 (8): 787-94.

    IntroductionUsing indirect calorimetry (IC), required energy demand may be determined. The SenseWear (SW) armband uses skin temperature, galvanic skin response, heat flux, and a 2-axis accelerometer to estimate daily energy expenditure (EE). The aim of the present study was to evaluate accuracy of the SenseWear measurements in critically ill and ventilated patients.Material And MethodsAfter approval of the local ethics committee and written informed consent, critically ill and ventilated patients were enrolled. During a 24-h study period EE was continuously measured using the SW armband (standardized position at right upper arm); an IC was performed additionally. Measurement bias (DeltaEE) was calculated as DeltaEE=EE(SW)-EE(IC). Daily energy expenditure of both techniques (IC vs. SW) was compared using regression analysis and the Bland Altman method. The t-Test for paired samples was used for statistical analysis, p<0.05 was considered statistically significant.Results And DiscussionIn total, 23 critically ill and ventilated patients (17 male, 6 female; means: 59.9+/-17.3 years; body mass index 28.0+/-6.3 kg/m(-2)) were investigated. A mean bias of DeltaEE=-565.65+/-1,748.07 kJ (-135.0+/-417.2 kcal) [range: -4,709.56+/-2,224.89 kJ (-1,124 to +531 kcal); p=0.3547] was calculated. Bland-Altman analysis revealed that SW slightly overestimates IC energy expenditure for critically ill patients in the hypo- and normocaloric range [<7,123 kJ/24 h: DeltaEE=+644.42+/-1,038.70 kJ (<1,700 kcal/24 h: DeltaEE=+153.8+/-247.9 kcal); p=0.0838], but significantly underestimated IC values in the hypercaloric range [>10,056 kJ/24 h: DeltaEE=-2,679.09+/-1,698.63 kJ (>2,400 kcal/24 h: DeltaEE=-639.4+/-405.4 kcal); p=0.0098].ConclusionsThe SenseWear armband is non-invasive, convenient and easy to handle, but has a significant measurement bias in the hypercaloric range. Although IC is still best suited to determining metabolic need in intubated patients, measurements with the SenseWear armband provide significant advantages, e.g. in non-intubated patients, and give a fair estimation of daily energy expenditure when used alone.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.