    Diagnostic accuracy of three-dimensional contrast-enhanced MR angiography at 3-T for acute pulmonary embolism detection: comparison with multidetector CT angiography.

    • Long Jiang Zhang, Song Luo, Benjamin M Yeh, Chang Sheng Zhou, Chun Xiang Tang, Yan'e Zhao, Lin Li, Ling Zheng, Wei Huang, and Guang Ming Lu.
    • Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China. Electronic address: kevinzhlj@163.com.
    • Int. J. Cardiol. 2013 Oct 12; 168 (5): 4775-83.

    BackgroundThree-dimensional contrast-enhanced MR pulmonary angiography (MRPA) is a suitable option for pulmonary embolism (PE) detection. However, there have been few reports on the diagnostic accuracy of MRPA for PE detection in a 3-T MR system. The purpose of this study was to evaluate the accuracy of MRPA in a 3-T MR system to detect acute PE with multidetector CT pulmonary angiography (CTPA) as reference standard.MethodsTwenty-seven patients (18 males and 9 females, mean age 38.9±14.4 years) underwent both MRPA and CTPA within 3 days (range, 0-3 days) for evaluating PE. Pulmonary emboli in MRPA were independently analyzed on a per-patient and per-lobe basis by two radiologists. CTPA was regarded as reference standard, which was evaluated by another two radiologists in consensus. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for PE detection were calculated. Weighted κ values were calculated to evaluate agreement between readers.ResultsTwenty-four patients had PE in 55 lung lobes in CTPA, while 3 patients had no PE detected. Readers 1 and 2 correctly detected 47 and 46 lung lobes having clots in 24 and 23 patients, corresponding to sensitivities, specificities, PPV, NPV, and accuracies of 100%, 100%, 100%, 100%, 100%; 100%, 66.7%, 96.0%, 100%, 96.4% on a per-patient basis and 85.5%, 100%, 100%, 90.9%, 94.1%; 83.6%, 93.7%, 90.2%, 89.2%, 89.6% on a per-lobe basis; respectively. Excellent inter-reader agreement (κ values=1.00 and 0.934; both P<0.001) were found for detecting PE on a per-patient and per-lobe analysis.ConclusionThree-dimensional contrast-enhanced MRPA with a 3-T MR system is a suitable alternative modality to CTPA to detect PE on a per-patient basis based on this small cohort study.© 2013.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…