-
AJNR Am J Neuroradiol · May 2009
Clinical TrialComputerized assessment of angiographic occlusion rate and coil density in embolized human cerebral aneurysms.
- C Sherif, G Bavinzski, C Dorfer, F Kanz, E Schuster, and H Plenk.
- Department of Neurosurgery, Medical University Vienna, Vienna, Austria. camillo.sherif@meduniwien.ac.at
- AJNR Am J Neuroradiol. 2009 May 1; 30 (5): 1046-53.
Background And PurposeComputerized methods have been introduced for more objective quantification of angiographic occlusion rate and coil density as parameters of successful embolization. This study aimed 1) to evaluate this new computerized method for angiographic occlusion rating and coil density calculations by comparison with corresponding histometric parameters from retrieved human aneurysms, and 2) to compare the new computerized method with the present standard of subjective angiographic occlusion rating.Materials And MethodsFrom 14 postmortem-retrieved human aneurysms, angiographic occlusion rate was determined by contrast medium attenuation-gradient distinction on digital subtraction angiographs after Guglielmi detachable coil (GDC) embolization. Angiographic coil density was calculated, approximating aneurysms as ellipsoid and coils as cylindric volumes. On surface-stained histologic ground sections of the respective aneurysms, the occluded aneurysm area and coil area were measured. Then, we calculated and compared the histometric occlusion rates and coil densities with the corresponding angiographic parameters by using the Wilcoxon paired signed-rank test and the Spearman rank correlation.ResultsComputerized angiographic occlusion rates (75%-100%) showed good correlation (r = 0.799; P < .01) with histometric occlusion-rates (61%-100%), resulting in no statistically significant differences (P = .2163). With 5.1% (+/-3.8), the mean difference between computerized angiographic occlusion rates and histometry was substantially lower compared with 10.7% (+/-8.7) mean difference between subjective angiographic estimations and histometry. Calculated angiographic coil density (13%-32%) significantly differed from histometric coil density (8%-35%; P < .05).ConclusionsFor recanalized aneurysms, computerized angiographic occlusion rating showed better correspondence with histometry compared with subjective angiographic occlusion rating. Clinical application of this new tool may lead to more objective cutoff values for re-embolization indications. The value of coil density calculations seems limited by the approximation of the aneurysms as ellipsoid volumes.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.