- Mark E Rupp, Lee A Sholtz, Dawn R Jourdan, Nedra D Marion, Laura K Tyner, Paul D Fey, Peter C Iwen, and James R Anderson.
- Division of Infectious Diseases, Department of Internal Medicine, University of Nebraska Medical Center, Omaha, USA. merupp@unmc.edu
- Clin. Infect. Dis. 2007 Jun 1; 44 (11): 1408-14.
BackgroundNeedleless intravascular catheter connector valves have been introduced into clinical practice to minimize the risk of needlestick injury. However, infection-control risks associated with these valves may be underappreciated. In March 2005, a dramatic increase in bloodstream infections was noted in multiple patient care units of a hospital in temporal association with the introduction of a needleless valve into use.MethodsSurveillance for primary bloodstream infection was conducted using standard methods throughout the hospital. Blood culture contamination rates were monitored. Cultures were performed using samples obtained from intravascular catheter connector valves.ResultsThe relative risk of bloodstream infection for the time period in which the suspect connector valve was in use, compared with baseline, was 2.79 (95% confidence interval, 2.27-3.43). In critical care units, the rate of primary bloodstream infection increased with the introduction of the valve from 3.87 infections per 1000 catheter-days to 10.64 infections per 1000 catheter-days (P<.001), and it decreased to 5.59 infections per 1000 catheter-days (P=.02) in the 6 months following removal of the device from use. Similarly, in inpatient nursing units, the rate of bloodstream infection increased from 3.47 infections per 1000 catheter-days to 7.3 infections per 1000 catheter-days (P=.02) following introduction of the device, and it decreased to 2.88 infections per 1000 catheter-days (P=.57) following removal of the device from use. Similar events occurred in the cooperative care units. The rate of blood culture contamination did not substantially change over the course of the study. Of 37 valves that were subjected to microbiological sample testing, 24.3% yielded microbes, predominantly coagulase-negative staphylococci.ConclusionA significant association between primary bloodstream infection and a needleless connector valve was observed. Evaluation of needleless connector valves should include a thorough assessment of infection risks in prospective randomized trials prior to their introduction to the market.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.