    Pressurized Metered-Dose Inhalers Versus Nebulizers in the Treatment of Mechanically Ventilated Subjects With Artificial Airways: An In Vitro Study.

    • Arzu Ari, Robert J Harwood, Meryl M Sheard, and James B Fink.
    • Department of Respiratory Therapy, Georgia State University, Atlanta, Georgia. arzuari@hotmail.com.
    • Respir Care. 2015 Nov 1; 60 (11): 1570-4.

    BackgroundThe primary focus of previous aerosol research during mechanical ventilation was the endotracheal tube (ETT). Consequently, there are limited data in the literature on the delivery of inhaled medications administered with different aerosol devices in mechanically ventilated patients with a tracheostomy tube (TT). The purpose of this study was to quantify and compare the efficiency of aerosol devices in a lung model of an intubated and mechanically ventilated adult with a TT.MethodsAn in vitro lung model was constructed to simulate a ventilator-dependent adult with a Portex TT and a Mallinckrodt ETT (8-mm inner diameter). Aerosol was collected distal to the bronchi of an adult mannikin on a filter attached to a passive test lung. A ventilator delivered adult breathing parameters (tidal volume 450 mL, breathing frequency 20 breaths/min, peak expiratory flow 40 L/min, and inspiratory-expiratory ratio 1:3) to the airway. A jet nebulizer and pressurized metered-dose inhaler (pMDI) were placed in the inspiratory limb of the circuit 15 cm from the Y-adapter. The jet nebulizer was operated at 8 L/min to deliver albuterol sulfate (2.5 mg/3 mL), whereas an albuterol pMDI was actuated 4 times with a spacer. Drug was eluted from the filter and analyzed by spectrophotometry.ResultsDrug delivered via a TT was marginally greater compared with an ETT using the jet nebulizer and pMDI (P = .10 and .046, respectively). Although delivery efficiency with the pMDI was 3-fold greater than with the jet nebulizer with both a TT and an ETT (P = .001 and .002, respectively), the jet nebulizer delivered greater drug mass compared with the pMDI with either a TT (P = .01) or an ETT (P = .005).ConclusionsAerosol drug delivery via a TT was greater than with an ETT, whereas the delivery efficiency of a pMDI via either airway was greater than that of a jet nebulizer.Copyright © 2015 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.