    Glucose measurement of intensive care unit patient plasma samples using a fixed-wavelength mid-infrared spectroscopy system.

    • James Krinsley, Kelly Bochicchio, Christopher Calentine, and Grant Bochicchio.
    • Division of Critical Care, Stamford Hospital, Columbia University College of Physicians and Surgeons, Stamford, Connecticut 06902, USA. jkrinsley@stamhealth.org
    • J Diabetes Sci Technol. 2012 Mar 1; 6 (2): 294-301.

    ObjectiveGlycemic control is a rapidly developing field in intensive care medicine with the aim of reducing mortality, morbidity, and cost. Current intensive care unit (ICU) glucose measurement technologies are susceptible to interference from medications, volume expanders, and other substances present in critically ill patients. We hypothesized that a fixed-wavelength mid-infrared (mid-IR) spectroscopy system would be accurate for measuring glucose levels of ICU patients.Research Design And MethodsThis is a prospective investigation of plasma samples from two different institutions treating a heterogeneous population of ICU patients. The first 292 samples were collected from 86 patients admitted to Stamford Hospital, and the next 352 samples were collected from 75 patients from three ICUs at the University of Maryland. Plasma samples were measured on a Fourier-transform infrared or a proprietary spectrometer, with a glucose prediction algorithm to correct for spectral interference, which were compared with reference measurements taken using a YSI 2300 glucose analyzer.ResultsGlucose values ranged from 24 to 343 mg/dl. Numerous medications and injury/disease states were observed in the patient populations, with metoprolol, fentanyl, and multiple organ failure the most prevalent. Despite these interferents, there was a high correlation (r ≥ 0.94) and low standard error (≤12.8 mg/dl) between the predicted glucose values and those of the YSI 2300 STAT Plus reference instrument in the three studies. A total of 95.1% of the 644 values in the three studies met International Organization for Standardization 15197 criteria.ConclusionThese results suggest that a fixed-wavelength mid-IR spectrometer can measure glucose accurately in the plasma of ICU patients.© 2012 Diabetes Technology Society.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…