-
Comparative Study
Left-right axial rotation within C1-2 after implant removal.
- Tobias Pitzen, Erbay Salman, Gregor Ostrowski, Thomas Welk, Michael Ruf, and Jörg Drumm.
- Zentrum für Wirbelsäulenchirurgie, Orthopaedie, und Traumatologie; and.
- J Neurosurg Spine. 2013 Dec 1; 19 (6): 688-93.
ObjectSurgical treatment of atlantoaxial injuries may be performed by a variety of surgical procedures, with each of these having its own specific advantages and disadvantages. To preserve the range of motion within the atlantoaxial joint after surgical treatment, posterior atlantoaxial screw fixation according to the method of Goel and Harms could be beneficial. This technique is not considered to fix the joint permanently if the screws are removed. However, this must not necessarily be true, especially if one notices that cervical joints have a tendency for rapid fusion after surgery. The objective of this study was to analyze left-right axial rotation following implant removal, with the following research questions addressed: 1) is there a relevant rotational left-right mobility in C1-2; 2) is there a difference in mobility depending on sex; 3) is there a correlation of mobility to age; 4) is there a correlation of mobility to the "implant-in-body time"; and 5) is neck pain improved by this method of surgical treatment?MethodsThis is a retrospective study in 10 patients who had received atlantoaxial fixation according to the Harms method following atlantoaxial injury. These patients had undergone implant removal after a mean time of 128 days, followed by functional atlantoaxial CT in left-right rotation. Statistical analysis was performed using the SPSS software package; significance was assumed for p < 0.05.ResultsThe following findings are reported. 1) Left-right axial rotation within the atlantoaxial joint was measured to be 17° (mean value) following implant removal. 2) There was no significant difference between men (20°) and women (14.8°) (p = 0.595). 3) Left-right axial rotation negatively correlated to the age of the patient (r = -0.646, p = 0.043). 4) "Implant-in-body time" did not influence left-right axial rotation (r = 0.04, p = 0.907) if the implants are removed within 90-180 days after surgery. 5) Neck pain as assessed by the patients themselves on the visual analog scale was 7.9 ± 1.1 preoperatively and 3.6 ± 1.2 (mean ± SD) after implant removal (p = 0.002).ConclusionsThe authors conclude that removal of the implants 3-6 months after posterior atlantoaxial fixation according to the method of Goel and Harms is beneficial for obtaining some axial rotation within the atlantoaxial joint. The range of motion preserved depends on the age of the patient.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.