• J Am Soc Echocardiogr · Nov 2002

    Comparative Study

    Continuous recording of pulmonary artery diastolic pressure and cardiac output using a novel ultrasound transducer.

    • P Anthony N Chandraratna, Ramandeep Brar, Sridhar Vijayasekaran, Qiu Xiong Chen, Gebeyehu T Niguse, Yasmeen Shaikh, and Heidi Cho.
    • Division of Cardiology, Los Angeles County, California, USA.
    • J Am Soc Echocardiogr. 2002 Nov 1; 15 (11): 1381-6.

    BackgroundThe feasibility of hands-free transthoracic continuous determination of pulmonary artery (PA) diastolic pressure (PAD) and cardiac output (CO) by Doppler ultrasound has not been previously demonstrated. We developed a 2.5-MHz spherical transducer mounted in an external housing to permit steering in 360 degrees (Contison). The external housing was attached to the chest wall using an adhesive patch.Methods And ResultsFifty patients in the coronary care department who had PA catheters had Doppler ultrasound studies. The 2.5-MHz spherical transducer was placed at the left sternal border to permit imaging of the pulmonic valve and was attached to a commercial ultrasound machine. The PA was imaged and its diameter measured. The pulmonary flow velocity signal was recorded and the time velocity integral obtained. The CO was calculated as: CO = time velocity integral of the PA systolic flow velocity signal x pi diameter(2) divided by 4 x heart rate. The pulmonary regurgitation signal was then recorded and the end-diastolic velocity of the regurgitant signal was measured. Right atrial pressure was assessed from the jugular venous pressure or from the size and pulsatility of the inferior vena cava. The PADP was calculated as: PADP = 4 end-diastolic velocity of the regurgitant signal(2) + right atrial pressure. The CO, PADP, and pulmonary wedge pressure were recorded from the PA catheter immediately after the ultrasound studies. Serial data were obtained every half hour or 1 hour up to a maximum of 5 hours. Adequate Doppler signals were obtained in 43 patients.ResultsThere was a good correlation between the PADP by Doppler versus PA catheter (r = 0.90, standard error of the estimate = 3.3 mm Hg); PADP by Doppler versus PA wedge pressure (r = 0.88, standard error of the estimate = 3.7 mm Hg); and CO by Doppler versus PA catheter (r = 0.92, standard error of the estimate = 0.7 L/min).ConclusionThe 2.5-MHz spherical transducer permitted accurate assessment of CO and PAD. This transducer could be of potential value in monitoring patients in the intensive care setting.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.