• J Neurosurg Anesthesiol · Oct 2011

    A novel technique for monitoring of fast variations in brain oxygen tension using an uncoated fluorescence quenching probe (Foxy AL-300).

    • Klaus Ulrich Klein, Stefan Boehme, Erik Kristopher Hartmann, Marc Szczyrba, Matthias David, Klaus Markstaller, and Kristin Engelhard.
    • Department of Anesthesiology, Intensive Care Medicine and Pain Therapy, Medical University Vienna, Vienna, Austria. ulrich.klein@meduniwien.ac.at
    • J Neurosurg Anesthesiol. 2011 Oct 1;23(4):341-6.

    BackgroundA novel uncoated fluorescence quenching probe allows fast measurement of oxygen tension in vessels and tissue. The present study reports the first use of the technology for dual measurements of arterial (paO(2)) and brain tissue oxygen tension (ptiO(2)) during hypoxic challenge in a pig model.MethodsEight pigs were anesthetized using fentanyl and propofol. Fluorescence quenching pO(2) probes (Foxy AL-300, Ocean Optics, Dunedin, FL) were placed in the ascending aorta (Foxy-paO(2)) and subcortically at 14 mm in brain tissue (Foxy-ptiO(2)). As reference, a clark-type electrode probe (Licox-ptiO(2)) was placed into brain tissue close to the Foxy probe (Licox, Integra Neurosciences, Plainsboro, NJ). Measurements were taken at baseline (FiO(2) 1.0), during episodes of apnea, and during recovery (FiO(2) 1.0).Statisticsdescriptive results.ResultsIndividual Foxy-paO(2), Foxy-ptiO(2), and Licox-ptiO(2) courses were related to episodes of apnea. The response time of the Foxy measurements was 10 Hz. Baseline values at FiO(2) 1.0 were Foxy-paO(2) 520±120 mm Hg, Foxy-ptiO(2) 62±24 mm Hg, and Licox-ptiO(2) 55±29 mm Hg; apnea values were Foxy-paO(2) 64±10 mm Hg, Foxy-ptiO(2) 37±12 mm Hg, and Licox-ptiO(2) 31±16 mm Hg; recovery values at FiO(2) 1.0 were Foxy-paO(2) 478±98 mm Hg, Foxy-ptiO(2) 78±26 mm Hg, and Licox-ptiO(2) 62±32 mm Hg.ConclusionsThe present study demonstrates the feasibility of pO(2) measurements in macrocirculation and cerebral microcirculation using a novel uncoated fluorescence quenching probe. The technology allows for real-time investigation of pO(2) changes at a temporal resolution of 0.05 to 10 Hz.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.