- A L Balogh, F Petak, G H Fodor, J Tolnai, Z Csorba, and B Babik.
- Department of Anaesthesiology and Intensive Therapy, University of Szeged, 6 Semmelweis u. H-6725, Szeged, Hungary Department of Medical Physics and Informatics, University of Szeged, 9 Koranyi fasor, H-6720, Szeged, Hungary.
- Br J Anaesth. 2016 Jul 1; 117 (1): 109-17.
BackgroundCapnography may provide useful non-invasive bedside information concerning heterogeneity in lung ventilation, ventilation-perfusion mismatching and metabolic status. Although the capnogram may be recorded by mainstream and sidestream techniques, the capnogram indices furnished by these approaches have not previously been compared systematically.MethodsSimultaneous mainstream and sidestream time and volumetric capnography was performed in anaesthetized, mechanically ventilated patients undergoing elective heart surgery. Time capnography was used to assess the phase II (SII,T) and III slopes (SIII,T). The volumetric method was applied to estimate phase II (SII,V) and III slopes (SIII,V), together with the dead space values according to the Fowler (VDF), Bohr (VDB), and Enghoff (VDE) methods and the volume of CO2 eliminated per breath ([Formula: see text]). The partial pressure of end-tidal CO2 ([Formula: see text]) was registered.ResultsExcellent correlation and good agreement were observed in SIII,T measured by the mainstream and sidestream techniques [ratio=1.05 (sem 0.16), R(2)=0.92, P<0.0001]. Although the sidestream technique significantly underestimated [Formula: see text] and overestimated SIII,V [1.32 (0.28), R(2)=0.93, P<0.0001], VDF, VDB, and VDE, the agreement between the mainstream and sidestream techniques in the difference between VDE and VDB, reflecting the intrapulmonary shunt, was excellent [0.97 (0.004), R(2)=0.92, P<0.0001]. The [Formula: see text] exhibited good correlation and mild differences between the mainstream and sidestream approaches [0.025 (0.005) kPa].ConclusionsSidestream capnography provides adequate quantitative bedside information about uneven alveolar emptying and ventilation-perfusion mismatching, because it allows reliable assessments of the phase III slope, [Formula: see text] and intrapulmonary shunt. Reliable measurement of volumetric parameters (phase II slope, dead spaces, and eliminated CO2 volumes) requires the application of a mainstream device.© The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.