• Neurophysiol Clin · Dec 2007

    Review

    Criteria for transcranial electrical motor evoked potential monitoring during spinal deformity surgery A review and discussion of the literature.

    • D-D Langeloo, H-L Journée, M de Kleuver, and J A Grotenhuis.
    • Department of Orthopedics, Institute for Spine Surgery and Applied Research (ISSAR) Sint Maartenskliniek, Hengstdal 3, 6522 JV, Nijmegen, The Netherlands. D.Langeloo@chello.nl
    • Neurophysiol Clin. 2007 Dec 1; 37 (6): 431-9.

    AbstractTranscranial electrical stimulated motor evoked potential monitoring (TES-MEP) has proven to be a successful and reliable neuromonitoring technique during spinal correction surgery. However, three criteria for TES-MEP monitoring have been described in the literature. This study aims at discussing and comparing the following criteria: (1) the "threshold level criterion" introduced by Calancie et al. (J Neurosurg 88 (1998) 457-70): a more than 100V over more than 1h increase of threshold level to get useful TES-MEP responses indicated neurological impairment; (2) the "amplitude criterion": for TES-MEP monitoring in corrective surgery of the spine, a more than 80% decrease of one or more response amplitudes was considered a valuable criterion for impending neurological deficits by Langeloo et al. (Spine 28 (2003) 1043-50); (3) "the morphology criterion": introduced in 2005 by Quinones et al. (Neurosurgery 56 (2005) 982-93), it is based on the morphology of the MEP-compound muscle action potentials (CMAP). The criterion was applied during TES-MEP monitoring during intramedullary spinal cord tumour resection. Neurological events are defined by a sharp decrease of response duration and/or waveform complexity and an increase in voltage threshold of 100V or greater. Although all methods have been reported to be successful during spinal surgery, the threshold criterion and the morphology change criterion carry several drawbacks. We consider the amplitude reduction method to be most useful during corrective spinal surgery. The sequences of observations and decisions during a TES-MEP monitoring that is based on this criterion are schematized in a flowchart.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…