• Bmc Infect Dis · Jan 2011

    Feasibility of magnetic bead technology for concentration of mycobacteria in sputum prior to fluorescence microscopy.

    • Heidi Albert, Patrick J Ademun, George Lukyamuzi, Barnabas Nyesiga, Yukari Manabe, Moses Joloba, Stuart Wilson, and Mark D Perkins.
    • FIND, Foundation for Innovative New Diagnostics, Kampala, Uganda. heidi.albert@finddiagnostics.org
    • Bmc Infect Dis. 2011 Jan 1; 11: 125.

    BackgroundDirect sputum smear microscopy is the mainstay of TB diagnosis in most low and middle income countries, and is highly specific for Mycobacterium tuberculosis in such settings. However it is limited by low sensitivity, particularly in HIV co-infected patients. Concentration by centrifugation has been reported to be more sensitive than direct smear preparation, but is only suitable for referral laboratories. Simpler concentration methods that could be applied in peripheral laboratories are urgently needed.MethodsWe evaluated the feasibility of an early prototype ligand-coated magnetic bead technology to concentrate M. tuberculosis prior to detection by LED-based fluorescence microscopy compared with direct Ziehl-Neelsen microscopy and direct and concentrated fluorescence microscopy in a reference laboratory in Kampala, Uganda. Results were compared with MGIT 960 liquid culture and Lowenstein-Jensen culture.ResultsCompared to culture, concentrated FM had significantly higher sensitivity than direct ZN (74.8% and 51.4%), magnetic bead-FM (65.4%) and direct FM (58.9%). The sensitivity of magnetic bead FM was significantly higher than direct ZN (p<0.001) but not significantly higher than direct FM (p=0.210). The specificity of magnetic bead FM and concentrated FM was significantly lower than direct ZN (88.6%, 94.3% and 98.9% respectively) and direct FM (99.4%). There was no significant difference in specificity between magnetic bead FM and concentrated FM. Allowing for blinded resolution of discrepant results, the specificity of magnetic bead FM increased to 93.1%. Direct microscopy was simpler than concentrated FM and Magnetic bead FM which both had a similar number of steps.ConclusionThe sensitivity of the early prototype magnetic bead FM was lower than concentrated FM, similar to direct FM, and significantly higher than direct ZN. Both magnetic bead and concentration by centrifugation led to reduced specificity compared with the direct smear methods. Some magnetic bead FM false positive results were not easily explained and should be further investigated. The prototype version of the magnetic bead procedure tested here was of similar complexity to concentration by centrifugation. As such, if the sensitivity of the magnetic bead FM could be improved in future versions of the technology, this may offer a viable alternative to centrifugation.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.