• Acad Emerg Med · Aug 2015

    Ultrasound Accurately Identifies Soft Tissue Foreign Bodies in a Live Anesthetized Porcine Model.

    • Turandot Saul, Sebastian D Siadecki, Gabriel Rose, Rachel Berkowitz, Danielle Matilsky, James Godbold, and Erin Moshier.
    • Division of Emergency Ultrasound, Department of Emergency Medicine, Mount Sinai St. Luke's Hospital and Mount Sinai Roosevelt Hospital, New York, NY.
    • Acad Emerg Med. 2015 Aug 1;22(8):950-4.

    BackgroundSome subcutaneous foreign bodies (FBs) are not easily visualized during physical examination and may not be detected on radiographic evaluation. Ultrasound (US) is capable of visualizing FBs of varying compositions. Previous studies have examined the use of US to detect FBs in deceased animal or human tissue. This study used live anesthetized porcine tissue to more closely model clinical conditions.ObjectivesThe objectives were to examine the test characteristics of US in the evaluation of FBs in living tissue and to evaluate if secondary findings such as surrounding edema and hematoma improve diagnostic accuracy.MethodsInstitutional Animal Care and Use Committee (IACUC) approval was obtained. FBs 1 cm in length and 1 to 3 mm in width were created from toothpicks (wood), 21-gauge needles (metal), and a broken ampule (glass) and inserted subcutaneously into an anesthetized 20-kg Yorkshire swine. There were 72 sites implanted with equal proportions of each FB type and null sites. Half of the FBs were inserted at time 0 and half were inserted after 2 hours. Immediately after placement, four blinded physicians performed US evaluations of the first 36 sites. At 2 hours after placement, they evaluated each of the original 36 sites and the 36 new sites. They documented the presence or absence of FBs and surrounding edema.ResultsAfter initial FB placement, 122 of the 144 interpretations (85%) were correct, with a sensitivity of 85% (95% confidence interval [CI] = 79% to 92%) and a specificity of 86% (95% CI = 76% to 98%). No sites demonstrated surrounding edema. At 2 hours after placement, 127 of 144 interpretations (88%) for these same sites were correct, with a sensitivity of 87% (95% CI = 82% to 93%) and a specificity of 89% (95% CI = 81% to 97%). Of the 108 observations (27 sites that contained FBs), eight of the 108 (7%) observations had surrounding edema (four glass, three wood, one metal). For the 36 new sites with FBs placed 2 hours later, 126 of the 144 interpretations (83%) were correct, with a sensitivity of 88% (95% CI = 82% to 94%) and a specificity of 83% (95% CI = 73% to 95%). No sites had surrounding edema present.ConclusionsUltrasound was sensitive, specific, and accurate in identifying FBs in live anesthetized porcine tissue. Surrounding edema or hematoma 2 hours after placement was so infrequently observed that it was not possible to determine its influence on the test characteristics.© 2015 by the Society for Academic Emergency Medicine.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.