-
- Thomas K Aldrich, Pragya Gupta, Sean P Stoy, Anthony Carlese, and Daniel J Goldstein.
- Chest. 2015 Dec 1; 148 (6): 1484-8.
BackgroundPulse oximetry fails when pulsations are weak or absent, common in patients with continuous flow left ventricular assist devices (LVADs). We developed a method to measure arterial oxygenation (Sao2) noninvasively in pulseless patients with LVADs.MethodsThe technique involves 5- to 10-s occlusions of radial and ulnar arteries on one hand. A fingertip is transilluminated alternately with light-emitting diodes emitting 660 nm (red) and 905 nm (infrared). During the approximately 1 s after release of occlusion, changing attenuance of each wavelength is measured and their red/infrared arterial blood attenuance ratio (R/IR) calculated. We studied five normal subjects breathing hyperoxic, normoxic, or hypoxic gas mixtures to establish a calibration curve, using standard pulse oximetry as the gold standard. We also studied seven pulseless patients with LVADs (two studied twice) at clinically determined oxygenation.ResultsNormal subject data showed close correlation of oxygen saturation by pulse oximetry (Spo2) with R/IR, (Spo2 = 111 - [26.7 × R/IR]; R2 = 0.975). For patients with LVADs, predicted Sao2 (from the calibration curve) tended to underestimate measured Sao2 (from arterial blood) by a clinically insignificant 1.1 ± 1.6 percentage points (mean ± SD), maximum 3.4 percentage points.ConclusionsPreliminary results in a small number of patients demonstrate that pulseless oximetry can be used to estimate arterial saturation with acceptable accuracy. A noninvasive oximeter that does not rely on pulsatile flow would be a valuable advance in assessing oxygenation in patients with LVADs, for whom the only current option is arterial puncture, which is painful, risks arterial injury, and only provides a snapshot evaluation of oxygenation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.