• Clin Physiol Funct Imaging · Sep 2012

    Relationship between peak cardiac pumping capability and indices of cardio-respiratory fitness in healthy individuals.

    • Djordje G Jakovljevic, Jelena Z Popadic-Gacesa, Otto F Barak, David Nunan, Gay Donovan, Michael I Trenell, Nikola G Grujic, and David A Brodie.
    • Institute for Ageing and Health, Newcastle University, Newcastle upon Tyne, UK. d.jakovljevic@ncl.ac.uk
    • Clin Physiol Funct Imaging. 2012 Sep 1; 32 (5): 388-93.

    AbstractCardiac power output (CPO) is a unique and direct measure of overall cardiac function (i.e. cardiac pumping capability) that integrates both flow- and pressure-generating capacities of the heart. The present study assessed the relationship between peak exercise CPO and selected indices of cardio-respiratory fitness. Thirty-seven healthy adults (23 men and 14 women) performed an incremental exercise test to volitional fatigue using the Bruce protocol with gas exchange and ventilatory measurements. Following a 40-min recovery, the subjects performed a constant maximum workload exercise test at or above 95% of maximal oxygen consumption. Cardiac output was measured using the exponential CO(2) rebreathing method. The CPO, expressed in W, was calculated as the product of the mean arterial blood pressure and cardiac output. At peak exercise, CPO was well correlated with cardiac output (r = 0·92, P<0·01), stroke volume (r = 0·90, P<0·01) and peak oxygen consumption (r = 0·77, P<0·01). The coefficient of correlation was moderate between CPO and anaerobic threshold (r = 0·47, P<0·01), oxygen pulse (r = 0·57, P<0·01), minute ventilation (r = 0·53, P<0·01) and carbon dioxide production (r = 0·56, P<0·01). Small but significant relationship was found between peak CPO and peak heart rate (r = 0·23, P<0·05). These findings suggest that only peak cardiac output and stroke volume truly reflect CPO. Other indices of cardio-respiratory fitness such as oxygen consumption, anaerobic threshold, oxygen pulse, minute ventilation, carbon dioxide production and heart rate should not be used as surrogates for overall cardiac function and pumping capability of the heart.© 2012 The Authors Clinical Physiology and Functional Imaging © 2012 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…