-
Clinical endocrinology · Aug 1999
Reproducibility of the cortisol response to stimulation with the low dose (1 microg) of ACTH.
- Y J Park, K S Park, J H Kim, C S Shin, S Y Kim, and H K Lee.
- Department of Internal Medicine, College of Medicine, Seoul National University, Seoul, Korea.
- Clin. Endocrinol. (Oxf). 1999 Aug 1; 51 (2): 153-8.
ObjectivePrevious studies have shown that the rapid ACTH stimulation test using a low dose of 1 microg is more sensitive than that using 250 microg ACTH for detecting subtle cases of adrenal insufficiency. However, there are controversies for the reproducibility of the 1 microg-test. To evaluate the reproducibility of the 1 microg-test, we assessed both day-to-day and diurnal variations of cortisol responses to 1 microg ACTH injection. In addition, optimum sampling time for the 1 microg-test was also determined.SubjectsAND DESIGN Eight healthy volunteers and five patients with secondary adrenal insufficiency were recruited. Healthy subjects were given 1 microg ACTH 3 times in the morning (0800 h) and 2 times in the afternoon (1600 h). Patients with adrenal insufficiency had 2-tests in the morning and 2 in the afternoon. Serum cortisol levels were measured every 10 minutes for 1 h after the injection.ResultsIn healthy subjects, basal and peak serum cortisol levels were significantly higher in the morning (P < 0.05), whereas maximum cortisol increments were higher in the afternoon (P < 0.001). In patients with adrenal insufficiency, basal and peak serum cortisol levels in the morning were not different from corresponding values in the afternoon. Intra-individual coefficient of variation (CV) of peak serum cortisol response to 1 microg ACTH ranged from 3.0 to 16.4% in healthy subjects and 10.0-34. 4% in patients. Also, there was a significant correlation between peak morning or afternoon cortisol levels after 1 microg ACTH injection given in different days in both healthy subjects and patients. Twenty-six of the 40 studies in healthy subjects showed peak response at 20 minutes, while nine showed it at 30 minutes Using the data acquired at 20 and 30 minutes, all 40 studies in healthy subjects showed normal results while none of 20 studies in patients was normal.ConclusionsWe conclude that the cortisol response to 1 microg ACTH stimulation was reproducible in both healthy subjects and patients with secondary adrenal insufficiency. In order to assess adrenal function more accurately with the 1 microg ACTH stimulation test, serum cortisol should be measured before and 20 and 30 minutes after ACTH injection.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.