Acta neurochirurgica · Dec 2002
Case ReportsImpact of brain shift on intraoperative neurophysiological monitoring with cortical strip electrodes.
- O Suess, Th Kombos, O Ciklatekerlio, R Stendel, S Suess, and M Brock.
- Department of Neurosurgery, Benjamin Franklin University Hospital, Free University of Berlin, Hindenburgdamm 30, 12200 Berlin, Germany.
- Acta Neurochir (Wien). 2002 Dec 1; 144 (12): 1279-89; discussion 1289.
BackgroundIntraoperative neurophysiological monitoring has become the standard procedure for locating eloquent regions of the brain. Such continuous electrical stimulation of motor pathways is usually applied by means of flat silicon-embedded electrodes placed directly on the motor cortex. However, shifting of the silicon strip on the cortical surface as well as electrode displacement due to brain shift underneath the electrode can lead to inaccurate recordings not directly caused by intraoperative impairment of the motor cortex or the motor pathways.MethodThis prospective study was conducted to quantify cortical brain shift during open cranial surgery and to assess its impact on electrode positioning in 31 procedures near the precentral gyrus. Three groups of different lesion volumes were distinguished. Movement of the cortex between opening of the dura and completion of tumor removal as well as cortical electrode shifting were digitally measured and analyzed.FindingsCortical surface structures evidenced a significantly larger shift (up to 23.4 mm) in comparison to the electrode strips (up to 4.2 mm) in lesions with a volume of over 20 ml. Cortex shifting highly correlated with lesion volume, whereas strip electrode movement was almost unidirectional and did not differ significantly among the three groups. However, the way they were placed (completely on the cortex vs. partly underlying or overlapping the craniotomy borders) affected the magnitude of their intraoperative displacement. As a consequence, 3 of the 31 cases (9.3%) showed a significant change in the recorded motor responses due to intraoperative dislocation of the stimulating electrode.InterpretationChanges in the location of cerebral structures due to intraoperative brain shift may exert a marked influence on intraoperative neurophysiological monitoring if cortical strip electrodes are used. Therefore, long-term monitoring of the central region requires continuous checking of the position of stimulating electrodes and, if necessary, correction of their location.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.