• J Orthop Trauma · Aug 1997

    Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?".

    • C T Mehlman and T G DiPasquale.
    • University of Cincinnati College of Medicine, Children's Hospital Medical Center, OH, USA.
    • J Orthop Trauma. 1997 Aug 1; 11 (6): 392-8.

    ObjectivesTo correlate the amount of radiation exposure to members of the orthopaedic surgical team based on their relative positions during a simulated fluoroscopically assisted orthopaedic procedure.DesignExperimental study using commercially available fluoroscopic units and dosimetry badges designed to measure "eye" (ocular lens), "shallow" (hands/skin), and "deep" (whole-body) radiation exposure.SettingStandard hospital operating room at a level one trauma center.ParticipantsDosimetry badge clusters at specified distances from a fluoroscopic x-ray beam. Represented positions were direct beam contact, surgeon (12 in/30.5 cm), first assistant (24 in/70 cm), scrub nurse (36 in/91.4 cm), and anesthesiologist (60 in/152.4 cm).InterventionDosimetry badges were systematically exposed by a protocol intended to maximize radiation scatter. A maximum time for continuous fluoroscope use was set at ten minutes.Main Outcome MeasurementsRadiation exposure readings from dosimetry badges processed by a commercially available dosimetry service.ResultsMaximum readings are reported. Direct beam contact resulted in approximately 4000 mrem/minute (40 mSv/min) of radiation exposure. Deep exposure for the surgeon and first assistant was 20 mrem/min (0.2 mSv/min) and 6 mrem/min (0.06 mSv/min), respectively. Superficial exposure was 29 mrem/min (0.29 mSv/min) for the surgeon and 10 mrem/min (0.1 mSv/min) for the first assistant. Eye exposure was 10 mrem/min (0.1 mSv/min) for the surgeon and 6 mrem/min (0.06 mSv/min) for the first assistant. At the scrub nurse position, no deep or eye exposure was detected. One positive badge for shallow exposure was noted at the scrub nurse position, reflecting a 2 mrem/min (0.02 mSv/min) exposure rate. After ten minutes of continuous exposure, badges assigned to the anesthesiologist position never registered any positive readings.ConclusionsThese results indicate that unprotected individuals working twenty-four inches (70 cm) or less from a fluoroscopic beam receive significant amounts of radiation, whereas those working thirty-six inches (91.4 cm) or greater from the beam receive an extremely low amount of radiation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.