• J. Cardiovasc. Electrophysiol. · Oct 2001

    Comparative Study

    Supraventricular arrhythmias in children and young adults with implantable cardioverter defibrillators.

    • B A Love, K S Barrett, M E Alexander, L M Bevilacqua, M R Epstein, J K Triedman, E P Walsh, and C I Berul.
    • Department of Cardiology, Children's Hospital, Harvard Medical School, Boston, Massachusetts 02115, USA.
    • J. Cardiovasc. Electrophysiol. 2001 Oct 1; 12 (10): 1097-101.

    IntroductionRapidly conducted supraventricular tachycardias (SVTs) can lead to inappropriate device therapy in implantable cardioverter defibrillator (ICD) patients. We sought to determine the incidence of SVTs and the occurrence of inappropriate ICD therapy due to SVT in a pediatric and young adult population.Methods And ResultsWe undertook a retrospective review of clinical course, Holter monitoring, and ICD interrogations of patients receiving ICD follow-up at our institution between March 1992 and December 1999. Of 81 new ICD implantations, 54 eligible patients (median age 16.5 years, range 1 to 48) were identified. Implantation indications included syncope and/or spontaneous/inducible ventricular arrhythmia with congenital heart disease (30), long QT syndrome (9), structurally normal heart (ventricular tachycardia/ventricular fibrillation [VT/VF]) (7), and cardiomyopathies (7). Sixteen patients (30%) received a dual-chamber ICD. SVT was recognized in 16 patients, with 12 of 16 having inducible or spontaneous atrial tachycardias. Eighteen patients (33%) received > or =1 appropriate shock(s) for VT/VF; 8 patients (15%) received inappropriate therapy for SVT. Therapies were altered after an inappropriate shock by increasing the detection time or rate and/or increasing beta-blocker dosage. No single-chamber ICD was initially programmed with detection enhancements, such as sudden onset, rate stability, or QRS discriminators. Only one dual-chamber defibrillator was programmed with an atrial discrimination algorithm. Appropriate ICD therapy was not withheld due to detection parameters or SVT discrimination programming.ConclusionSVT in children and young adults with ICDs is common. Inappropriate shocks due to SVT can be curtailed even without dual-chamber devices or specific SVT discrimination algorithms.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…