• J Clin Monit · Nov 1993

    The fidelity and dynamic response of fluid-filled catheter systems for direct measurement of lumbar cerebrospinal fluid pressure.

    • M Kumar, E Werner, and M J Murray.
    • Mayo Clinic, Department of Anesthesiology, Rochester, MN 55905.
    • J Clin Monit. 1993 Nov 1; 9 (5): 314-20.

    ObjectiveThe purpose of this study was to determine the fidelity of pressure signals transmitted through long, narrow (epidural) catheters inserted into the lumbar intrathecal space.MethodsUsing a model of the spinal canal we tested three epidural catheters: 20-gauge Arrow, 20-gauge Abbott, 21-gauge Portex. We (1) determined the damping coefficient and natural frequency of the three catheters, (2) correlated the static pressures measured using the three catheters compared to the true pressure in the intrathecal space, and (3) compared the response time of the three catheters connected to transducers vs U-tube manometers.ResultsThe three catheters had high damping coefficients (alpha) (Arrow, 0.75; Abbott, 0.85; Portex, 1.10) and low natural frequencies (Arrow, 15.23 Hz; Abbott, 12.83 Hz; Portex, 9.09 Hz). The dynamic response characteristics of the catheter with the largest internal diameter (20-gauge Arrow) were adequate to reproduce pulsatile cerebrospinal fluid pressure reliably. Smaller catheters tracked the mean pressure, although oscillations were damped. Static pressure measurements from all three catheters showed good correlation with test pressures (r = 0.99; p < 0.001). Using the U-tube manometer, it required 170, 140, and 130 minutes for the Portex, Abbott, and Arrow catheters, respectively, to equilibrate with a test pressure of 30 cm H2O. The rate of rise in the U-tube manometer pressure was limited by the rate of fluid flow through the catheters.ConclusionsWe found that a catheter of at least 20 gauge connected to a transducer could record pressures in the cerebrospinal fluid compartment with a high degree of fidelity. The prolonged time to reach equilibrium made U-tube manometry unsuitable for clinical use.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…