• Anesthesiology · Jan 1989

    Transtracheal Doppler: a new procedure for continuous cardiac output measurement.

    • J H Abrams, R E Weber, and K D Holmen.
    • Department of Surgery, University of Minnesota, Minneapolis 55455.
    • Anesthesiology. 1989 Jan 1; 70 (1): 134-8.

    AbstractAn endotracheal tube with a 5 mm diameter ultrasonic transducer incorporated into its distal end was inserted into the tracheas of six anesthetized dogs. The device provides for ultrasound measurement of aortic diameter and blood velocity in the ascending aorta to obtain cardiac outputs. Because measurements are made proximal to the origins of the aortic arch vessels, total cardiac output is obtained. Procedures for measurement of aortic diameter, aortic blood velocity, and cardiac output are discussed. The resulting data were used to empirically determine the angle of incidence of the ultrasound beam that gave the best least squares fit over a range of thermodilution cardiac outputs. For an angle of incidence of 62.3 degrees, the relationship between cardiac output determined by thermal dilution and by transtracheal Doppler was transtracheal Doppler cardiac output = -.69 + 1.19 thermal dilution cardiac output. R2 = .82. The results from this preliminary assessment of the feasibility of measuring cardiac output in dogs using transtracheal Doppler suggest that additional studies should be pursued. Additional issues that require investigation include confirmation of constancy of human anatomy and demonstration of lack of tracheal trauma from the Doppler equipped endotracheal tube.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…