• Respiratory medicine · Aug 2003

    Randomized Controlled Trial Comparative Study Clinical Trial

    Comfort and pressure profiles of two auto-adjustable positive airway pressure devices: a technical report.

    • Katrien B Hertegonne, Pascal M Proot, Romain A Pauwels, and Dirk A Pevernagie.
    • Department of Respiratory Diseases, Ghent University Hospital, De Pinteloaan 185, Gent 9000, Belgium.
    • Respir Med. 2003 Aug 1; 97 (8): 903-8.

    Study ObjectivesThe purpose of this study was to compare comfort parameters and pressure profiles of the AutoSet (Resmed) and the SOMNOsmart (Weinmann), two auto-adjustable positive airway pressure (APAP) devices.SettingThe sleep disorders center of a university hospital.DesignA single-blind randomized trial protocol was applied. A split night procedure allowed each patient to be treated in a crossover fashion with both APAP devices during one overnight study.Patients And MethodsFifty consecutive obstructive sleep apnea (OSA) patients were recruited. Each patient filled out an evaluation form for both devices after the study night. Visual analogue scales were used to score four comfort measures. Three CPAP outcomes generated by the devices (P50, P95 and Pmax) were assessed, compared with each other and correlated with the individually predicted CPAP (Ppred).ResultsForty-five males and 5 females, mean age 53.0 years, body mass index 31.0, were included. The mean apnea-hypopnea index was 58.7, the mean arousal index was 54.3. Mean CPAP-compliance before the titration study was 4.9 h per night. Comparison of the two devices regarding the effect on the subjective sleep quality parameters showed no differences. The AutoSet pressure outcomes correlated significantly better with Ppred in comparison with the SOMNOsmart. The P50 and P95 but not the Pmax values were significantly lower in the SOMNOsmart as compared with the AutoSet (P50: 5.1+/-1.3 vs 7.1 +/- 1.9 mbar, P<0.0001; P95: 7.8+/-3.0 vs 9.6+/-1.9 mbar, P<0.0005; Pmax: 10.0+/-3.4 vs 10.8+/-1.8 mbar, NS).ConclusionWhile the subjective tolerance of the two APAP machines was comparable, these devices were characterized by different pressure profiles. The pressure parameters of the AutoSet correlated better with Ppred than those of the SOMNOsmart.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…