-
Randomized Controlled Trial Multicenter Study
Evaluation of auto bi-level algorithm to treat pressure intolerance in obstructive sleep apnea.
- Nigel Ball, Nancy Gordon, Eileen Casal, and James Parish.
- Swedish Medical Center, Seattle, WA, USA.
- Sleep Breath. 2011 Sep 1; 15 (3): 301-9.
PurposeThe objective of this study was to evaluate whether a new auto-adjusting bi-level algorithm was comparable to a standard method for prescribing bi-level therapy.MethodsThis study was a prospective randomized, double-blinded crossover evaluation of the equivalency of the auto-adjusting bi-level mode (VAuto™) compared to standard bi-level mode, using a pre-determined difference in Apnea-Hypopnea Index (AHI) of five events per hour. Data were obtained during sleep studies performed on two separate nights. Twenty-two subjects met the entry criteria and were enrolled in the study at four investigational sites in the USA.ResultsMean AHI for the auto-adjusting bi-level mode was 6.2 ± 5.4 events per hour and for the standard bi-level mode 8.3 ± 5.8 events per hour. The AHI for the two modes were clinically equivalent. The difference in median pressure between these two modes was -3.8 cm H(2)O ± 3.6 (p = 0.0008) in favor of the auto-adjusting bi-level mode. In addition, the maximum pressure was significantly higher in the auto-adjusting bi-level mode (16.0 cm H(2)O vs. 14.1 cm H(2)O, p = 0.02).ConclusionsOur results demonstrated that the auto-adjusting bi-level mode normalized AHI comparable to the standard bi-level mode. The results of this study have several significant implications for the clinical management of sleep apnea. Obstructive sleep apnea (OSA) is a common condition and is associated with untoward complications. Non-compliance with positive airway pressure (PAP) limits the efficacy of the PAP therapy. The auto-adjusting bi-level mode provides a potentially reliable alternative for sleep clinicians faced with prescribing bi-level PAP for non-compliant patients. This study documents that this type of auto-adjusting device provides effective treatment of OSA.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.