Comparative Study Clinical Trial
Comparison of hollow-fiber membrane oxygenators in terms of pressure drop of the membranes during normothermic and hypothermic cardiopulmonary bypass in neonates.
- Akif Undar, W Richard Owens, Mary Claire McGarry, Deborah L Surprise, Vicki D Kilpack, Maryann W Mueller, E Dean McKenzie, and Charles D Fraser.
- Congenital Heart Surgery Service, Texas Children's Hospital, Houston, USA. aundar@psu.edu
- Perfusion. 2005 May 1; 20 (3): 135-8.
UnlabelledThe objective of this study was to investigate the effects of two hollow-fiber membrane oxygenators, the Capiox SX10 and the Lilliput 901, on pressure drop of the membranes during normothermic and hypothermic cardiopulmonary bypass (CPB) in neonates.MethodsTwenty-six congenital heart surgery patients (n = 13 in each group) with a mean weight of 3 kg were included in this study. Pressure drops of the membranes, pre- and post-oxygenator extracorporeal circuit pressures (ECC) were recorded during normothermic CPB, hypothermic CPB (20 degrees C) and after rewarming. There were no differences between the groups in mean arterial pressure, pump flow rate, temperature, duration of CPB, crossclamp time or the severity of the surgical repairs.ResultsPressure drop of the Capiox SX10 oxygenator was significantly lower during normothermic (32 +/- 10 versus 55 +/- 16 mmHg, p < 0.001), hypothermic (38 +/- 15 versus 72 +/- 18 mmHg, p < 0.001) and post-rewarming (42 +/- 13 versus 72 +/- 21 mmHg, p < 0.001) periods compared to the Lilliput oxygenator. In the Capiox group, the pre-oxygenator ECC pressure was also significantly lower during normothermic CPB (142 +/- 27 versus 184 +/- 43 mmHg, p < 0.01), hypothermic CPB (162 +/- 30 versus 199 +/- 38 mmHg, p < 0.01) and after rewarming periods (172 +/- 32 versus 212 +/- 42 mmHg, p < 0.01). Post-oxygenator pressures in the Capiox group were also lower than in the Lilliput group, but results were not statistically significant.ConclusionsThese results suggest that the Capiox SX10 hollow-fiber membrane oxygenator produced significantly lower membrane pressure drops and pre- and post-oxygenator ECC during normothermic and hypothermic CPB. Thus, blood trauma with the Capiox during extracorporeal circulation may be significantly lower compared to the Lilliput. Further studies, including the level of complements, platelets, neutrophils and cytokines, with these oxygenators are warranted.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.