• J. Vasc. Surg. · Oct 2000

    Does the endovascular repair of aortoiliac aneurysms pose a radiation safety hazard to vascular surgeons?

    • E C Lipsitz, F J Veith, T Ohki, S Heller, R A Wain, W D Suggs, J C Lee, S Kwei, K Goldstein, J Rabin, D Chang, and M Mehta.
    • Division of Vascular Surgery, Department of Surgery, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY 10467, USA. Elipshitz@aol.com
    • J. Vasc. Surg. 2000 Oct 1; 32 (4): 704-10.

    ObjectivesEndovascular aortoiliac aneurysm (EAIA) repair uses substantial fluoroscopic guidance that requires considerable radiation exposure. Doses were determined for a team of three vascular surgeons performing 47 consecutive EAIA repairs over a 1-year period to determine whether this exposure constitutes a radiation hazard.MethodsTwenty-nine surgeon-made aortounifemoral devices and 18 bifurcated devices were used. Three surgeons wore dosimeters (1) on the waist, under a lead apron; (2) on the waist, outside a lead apron; (3) on the collar; and (4) on the left ring finger. Dosimeters were also placed around the operating table and room to evaluate the patient, other personnel, and ambient doses. Exposures were compared with standards of the International Commission on Radiological Protection (ICRP).ResultsTotal fluoroscopy time was 30.9 hours (1852 minutes; mean, 39.4 minutes per case). Yearly total effective body doses for all surgeons (under lead) were below the 20 mSv/y occupational exposure limit of the ICRP. Outside lead doses for two surgeons approximated recommended limits. Lead aprons attenuated 85% to 91% of the dose. Ring doses and calculated eye doses were within the ICRP exposure limits. Patient skin doses averaged 360 mSv per case (range, 120-860 mSv). The ambient (> 3 m from the source) operating room dose was 1.06 mSv/y.ConclusionsAlthough the total effective body doses under lead fell within established ICRP occupational exposure limits, they are not negligible. Because radiation exposure is cumulative and endovascular procedures are becoming more common, individuals performing these procedures must carefully monitor their exposure. Our results indicate that a team of surgeons can perform 386 hours of fluoroscopy per year or 587 EAIA repairs per year and remain within occupational exposure limits. Individuals who perform these procedures should actively monitor their effective doses and educate personnel in methods for reducing exposure.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…