• J. Vasc. Surg. · Aug 1997

    Hemostatic efficacy of a fibrin sealant-based topical agent in a femoral artery injury model: a randomized, blinded, placebo-controlled study.

    • M R Jackson, S A Friedman, A J Carter, V Bayer, J R Burge, M J MacPhee, W N Drohan, and B M Alving.
    • Department of Hematology and Vascular Biology, Walter Reed Army Institute of Research, Washington, DC 20307-5100, USA.
    • J. Vasc. Surg. 1997 Aug 1; 26 (2): 274-80.

    PurposeThe efficacy of currently available topical hemostatic agents requires the formation of fibrin generated from circulating blood. Fibrin sealant, which is prepared from high concentrations of thrombin and fibrinogen, has been used in liquid form to promote hemostasis during vascular surgery. In a blinded, randomized, placebo-controlled fashion, we evaluated a dry dressing of purified, viral-inactivated human fibrinogen and human thrombin in a large animal model of arterial injury.MethodsDressings were prepared by application of a layer of lyophilized human fibrin sealant or immunoglobulin G (IgG, control) to a silicone backing material. Six anesthetized female Yorkshire pigs (16 to 27 kg) received bilateral, 4 mm longitudinal femoral arteriotomies after surgical exposure of the arteries. The arteriotomies were not closed. In each animal a fibrin sealant dressing was applied to one artery and a control dressing to the other. Each dressing was secured on the arteriotomy by a mechanical device. After application of the dressings, blood flow was restored to each limb for 1 hour. The compressive device was released for 5 seconds at intervals of 15 minutes to assess hemostasis. Blood flow was measured distal to each arteriotomy with a dual-channel flowmeter to adjust equal bilateral compression.ResultsBlood loss (mean +/- SEM) was significantly less from the arteriotomy treated with the fibrin-based dressing compared with the control dressing (4.9 +/- 4.0 ml versus 82.3 +/- 11.1 ml; p = 0.0005). Complete hemostasis was achieved at the first 15-minute interval in five of six arteriotomies treated with fibrin sealant and in none of the six control arteriotomies during 1 hour of assessment (p = 0.03). Blood flow through each femoral artery at baseline was the same in both treatment and control arteries (fibrin sealant, 114.2 +/- 17.4 ml/min; control, 106.7 +/- 16.5 ml/min; p = 0.24) and was not significantly different throughout the experiment.ConclusionsFibrin-based dressings provide effective hemostasis in a large animal model of arterial injury. Further development of these dressings will address optimal formulation and configuration for clinical use. Our results suggest that fibrin-based dressings will be effective in promotion of hemostasis in arterial bleeding, without compromising blood flow.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…