• Int. J. Cardiol. · Aug 2013

    Choosing between velocity-time-integral ratio and peak velocity ratio for calculation of the dimensionless index (or aortic valve area) in serial follow-up of aortic stenosis.

    • Judith A Finegold, Charlotte H Manisty, Fabrizio Cecaro, Nilesh Sutaria, Jamil Mayet, and Darrel P Francis.
    • International Centre for Circulatory Health, National Heart and Lung Institute, London, UK. JudyFinegold@doctors.org.uk
    • Int. J. Cardiol. 2013 Aug 20; 167 (4): 1524-31.

    BackgroundIt remains unclear which echocardiographic measure is most suitable for serial measurement in real-world aortic stenosis (AS) follow-up. We determine whether the dimensionless index (DI) between aortic valve and left ventricular outflow tract velocities is measured more consistently using velocity-time-integral (VTI) or peak velocities (V(peak)) in real life.MethodsSerial echocardiograms acquired within 6 months in subjects with AS were analysed with blinding, to compare the variability over time of DI calculated using V(peak), with that of DI calculated using VTI.ResultsPaired echocardiograms, acquired on average 72 days apart, were analysed from 70 patients with a range of severities of AS (59% severe). DI, calculated using either V(peak) or VTI, did not significantly change over this short time. Coefficient of variation was significantly better when DI was calculated using V(peak) than VTI (12.6 versus 25.4%, p<0.0001). The variabilities of mean and peak trans-aortic valve 4v(2) and left ventricular outflow tract VTI were no better: 26.9%, 19.1% and 22.1% respectively.ConclusionsSerially-followed variables require minimal noise to maximise detection of genuine change. For AS surveillance, calculating DI--or effective orifice area--from the ratio of V(peak) rather than VTIs would reduce 95% confidence intervals from ± 51% to a still-disappointing ± 25%. Guidelines recommend noisy surveillance measures, causing conscientious echocardiographers to 'peek' at previous values, and impairing clinicians' faith in echocardiographically-observed changes when making clinical decisions. For us in echocardiography to improve our ability to contribute to AS follow-up requires us to first acknowledge and discuss this honestly.Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…