-
- L D Martin, J F Rafferty, R C Wetzel, and F R Gioia.
- Department of Anesthesiology and Critical Care Medicine, Johns Hopkins Medical Institution, Baltimore, Maryland 21205.
- Anesthesiology. 1989 Dec 1; 71 (6): 977-81.
AbstractVolume ventilation by demand flow ventilators significantly increases work of breathing during inspiration. Although various ventilator modifications and different modes of ventilation have been developed, there have been few studies regarding imposed work of breathing in infants and children. This study was designed to evaluate several modifications of a commercially available demand flow ventilator designed to shorten response time (tr) and decrease the imposed work (Wi) involved in opening the demand valve. Minimum withdrawal volume (Vmin), maximum negative pressure (P mneg), and tr were measured. Wi was defined as the product of Vmin and P mneg. Seven Siemens Servo 900C ventilators were tested under 16 different trial conditions with four variables: 1) mode of ventilation (synchronized intermittent mandatory ventilation [SIMV] vs. pressure support ventilation [PSV]); 2) caliber of circuit tubing (adult vs. pediatric); 3) location of airway pressure monitor (distal vs. proximal); and 4) ventilator trigger sensitivity (0 cm H2O--high vs. -2 cm H2O--low). Vmin, Pmneg, and Wi were all decreased (P less than .05) while tr was unaffected by changing ventilator trigger sensitivity from low to high. Wi was decreased by pediatric tubing and proximal airway pressure monitoring only when low trigger sensitivity was used. PSV and proximal airway monitoring shortened tr. The authors conclude that the use of pediatric circuit tubing and proximal airway pressure monitoring with a Siemens Servo 900C ventilator significantly improved ventilator performance.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.