• Haematologica · Dec 1999

    Interference of lupus anticoagulants in prothrombin time assays: implications for selection of adequate methods to optimize the management of thrombosis in the antiphospholipid-antibody syndrome.

    • P Della Valle, L Crippa, A M Garlando, E Pattarini, O Safa, S Viganò D'Angelo, and A D'Angelo.
    • Coagulation Service and Thrombosis Research Unit, Scientific Institute H S. Raffaele, Milan, Italy.
    • Haematologica. 1999 Dec 1; 84 (12): 1065-74.

    Background And ObjectiveProlonged anticoagulation aiming at International Normalized Ratio (INR) values > 3.0 has been recommended for patients with thrombosis and the antiphospholipid-antibody syndrome. We evaluated the influence of anticoagulant antibodies in two different prothrombin time (PT) assays carried out on plasma from lupus anticoagulant patients on oral anticoagulation.Design And MethodsINR values obtained with a combined (final test plasma dilution 1:20) and a recombinant (final test plasma dilution 1:3) thromboplastin were compared in 17 patients with persistent lupus anticoagulants (LA) receiving oral anticoagulant treatment and monitored for 69.8 patient-years. Doses of anticoagulant drugs were always assigned based on the results obtained with the combined thromboplastin, aiming at a target INR of 2.5 or 3.0 for patients with venous or arterial thromboembolic disease. Paired determinations with both reagents were also obtained throughout the study period in 150 patients on stable oral anticoagulation but free of antiphospholipid antibodies. Total IgG fractions were purified from selected patients to evaluate effect in the two PT assay systems.ResultsNo patient experienced recurrence of thrombosis or major bleeding complications (95% confidence interval: 0.1-6.5 per 100 patient-years). INR values with the recombinant reagent were significantly higher than with the combined reagent in 8 LA patients (mean DINR ranging from 0.17 to 0.54) of the degree of anticoagulation was overestimated in all but one LA patients with the recombinant reagent when compared to the DINR observed in non-LA patients (-0.64 +/- 0.42). The anti-cardiolipin IgG titer (r(2) = 0.43, p = 0.004) and the anti-b(2)GPI IgG titer (r(2) = 0.30, p = 0.023) were positively associated with the mean deltaINR observed in LA patients. When added to plasmas with different levels of vitamin K-dependent factors, total IgG fractions from 6 LA patients with significant overestimation of the INR with the recombinant reagent (mean DINR ranging from 0.17 to 0.54, group 1) and from 7 LA patients with mean deltaINR < or = 0.0 (ranging from -0.25 to 0.04, group 2) reproduced the effects observed ex vivo in the two assay systems. However, when total IgG fractions were tested at the same final concentration in the two PT assay systems, there was no difference in the clotting times determined with total IgG fractions from group 1 and group 2 LA patients. Addition of negatively charged liposomes (0.4 and 0.8 mg/mL final concentrations) to platelet free plasma from LA-free patients on stable oral anticoagulation caused a 20% to 48% prolongation of the prothrombin time determined with the recombinant reagent. In contrast, no significant prolongation of the prothrombin time determined with the recombinant reagent was observed upon addition of negatively charged liposomes to plasma from group 1 LA patients.Interpretation And ConclusionsThese results confirm previous suggestions of assay-dependency of INR values in LA patients on oral anticoagulation. For these patients, accurate INR values may be obtained using combined thromboplastin reagents that permit testing at high plasma dilution.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.