• Oncology nursing forum · Apr 2002

    Comparative Study

    Comparing the results of coagulation tests on blood drawn by venipuncture and through heparinized tunneled venous access devices in pediatric patients with cancer.

    • Pamela S Hinds, Alice Quargnenti, Jami Gattuso, Deo Kumar Srivastova, Xin Tong, Linda Penn, Nancy West, Patricia Cathey, Darlene Hawkins, Judith Wilimas, Matthew Starr, and David Head.
    • Division of Patient Care Services, St. Jude Children's Research Hospital, Memphis, TN, USA. pam.hinds@stjude.org
    • Oncol Nurs Forum. 2002 Apr 1; 29 (3): E26-34.

    Purpose/ObjectivesTo compare the accuracy of three coagulation tests (prothrombin time [PT], activated partial thromboplastin time [aPTT], and fibrinogen [FBG]) performed on blood samples collected through heparinized tunneled venous access devices (TVADs) with those from venipuncture.DesignDescriptive comparative with patients serving as their own controls.SettingPediatric comprehensive care setting for children and adolescents experiencing catastrophic diseases.Sample53 patients who had TVADs, had not received asparaginase during the previous 14 days, and had coagulation studies ordered. Patients ranged in age from 2-20 years (mean = 9.2 years, SD = 5). The most common diagnoses were neuroblastoma and acute myelocytic leukemia.MethodsBlood was collected through TVADs within seconds of collection of the venipuncture sample. The first 3 ml of blood from a TVAD was discarded; the research nurse then drew three sequential samples of 3 ml each. Laboratory personnel were blinded to the source of all four samples until all analyses had been completed.Main Research VariablesPT, aPTT, and FBG.FindingsFor all patients, results of PT, aPTT, and FBG tests on each of the three blood samples obtained through the TVAD differed significantly from results of the same tests on blood obtained by venipuncture.ConclusionsThese findings indicate that neither a 6 ml, 9 ml, nor 12 ml discard from a heparinized TVAD is sufficient to yield clinically trustworthy PT, aPTT, or FBG values.Implications For NursingNurses who have been persuaded by patients or parents to withdraw blood samples for coagulation indicators from a TVAD rather than from a venipuncture should have access to this research-based information that the three indicators, particularly aPTT, differ significantly from each other as to make it unreliable and potentially unsafe to sample blood from a TVAD to assess coagulation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…