• J. Heart Lung Transplant. · May 2013

    Antithrombotic strategies in children receiving long-term Berlin Heart EXCOR ventricular assist device therapy.

    • Jennifer M Rutledge, Sujata Chakravarti, M Patricia Massicotte, Holger Buchholz, David B Ross, and Umesh Joashi.
    • Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada. jennifer.rutledge@albertahealthservices.ca
    • J. Heart Lung Transplant. 2013 May 1; 32 (5): 569-73.

    BackgroundThromboembolic events while receiving ventricular assist device (VAD) support remain a significant cause of morbidity and mortality despite standard anti-coagulation and anti-platelet therapies. The use of bivalirudin and epoprostenol infusions as an alternate anti-thrombotic (AT) regimen in pediatric VAD patients was reviewed.MethodsThis was a retrospective record review of 6 pediatric patients (aged ≤17 years) at 2 institutions treated with bivalirudin and epoprostenol infusions while being supported with the Berlin Heart EXCOR (Berlin Heart GmbH, Berlin, Germany) VAD.ResultsSix patients (age, 0.8-14 years; weight, 6.7-29.7 kg) were treated. Diagnoses included cardiomyopathy in 2 and congenital heart disease in 4. VAD support was left VAD in 2 and bi-VAD in 4, with duration of support of 21 to 155 days. Three patients required extracorporeal membrane oxygenation before VAD support. Bivalirudin/epoprostenol was used after recurrent thromboses on conventional medication in 3 patients, heparin-induced thrombocytopenia in 2, and in 1 patient considered high risk with a prosthetic mitral valve. The bivalirudin dose was titrated to partial thromboplastin time (PTT) of 1.5- to 2-times baseline (0.1-0.8 mg/kg/hour); the epoprostenol dose was 2 to 10 ng/kg/min. Additional anti-platelet agents included acetylsalicylic acid, dipyridamole, and clopidogrel in 5 patients each. No bleeding complications occurred. One patient sustained a cerebrovascular infarct on therapy, with subsequent complete recovery. No other complications occurred. Five patients underwent successful transplantation, and 1 patient died of multisystem organ failure.ConclusionsThis report provides data on estimated safety and efficacy of bivalirudin and epoprostenol as an AT strategy in pediatric patients on extended VAD support. The short drug half-life and predictable AT response facilitated conversion to standard AT regimens at the time of transplantation (heparin-induced thrombocytopenia-negative patients). These agents should be considered for management of pediatric VAD patients when standard regimens fail.Copyright © 2013 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…