-
J. Clin. Microbiol. · Aug 2015
Comparative StudyA Novel Quantitative Sampling Technique for Detection and Monitoring of Clostridium difficile Contamination in the Clinical Environment.
- Shanom Ali, Monika Muzslay, and Peter Wilson.
- University College Hospital, Clinical Microbiology and Virology, London, United Kingdom shanom.ali@uclh.nhs.uk.
- J. Clin. Microbiol. 2015 Aug 1; 53 (8): 2570-4.
AbstractThe horizontal transmission of Clostridium difficile in the hospital environment is difficult to establish. Current methods to detect C. difficile spores on surfaces are not quantitative, lack sensitivity, and are protracted. We propose a novel rapid method to detect and quantify C. difficile contamination on surfaces. Sponge swabbing was compared to contact plate sampling to assess the in vitro recovery of C. difficile ribotype 027 contamination (∼10(0), 10(1), or 10(2) CFU of spores) from test surfaces (a bed rail, a stainless steel sheet, or a polypropylene work surface). Sponge swab contents were concentrated by vacuum filtration, and the filter membrane was plated onto selective agar. The efficacy of each technique for the recovery of C. difficile from sites in the clinical environment that are touched at a high frequency was evaluated. Contact plates recovered 19 to 32% of the total contamination on test surfaces, whereas sponge swabs recovered 76 to 94% of the total contamination, and contact plates failed to detect C. difficile contamination below a detection limit of 10 CFU/25 cm(2) (0.4 CFU/cm(2)). In use, contact plates failed to detect C. difficile contamination (0/96 contact plates; 4 case wards), while sponge swabs recovered C. difficile from 29% (87/301) of the surfaces tested in the clinical environment. Approximately 74% (36/49) of the area in the vicinity of the patient was contaminated (∼1.34 ± 6.88 CFU/cm(2) C. difficile spores). Reservoirs of C. difficile extended to beyond the areas near the patient: a dirty utility room sink (2.26 ± 5.90 CFU/cm(2)), toilet floor (1.87 ± 2.40 CFU/cm(2)), and chair arm (1.33 ± 4.69 CFU/cm(2)). C. difficile was present on floors in ∼90% of case wards. This study highlights that sampling with a contact plate may fail to detect C. difficile contamination and result in false-negative reporting. Our sponge sampling technique permitted the rapid and quantitative measurement of C. difficile contamination on surfaces with a sensitivity (limit, 0 CFU) greater than that which is otherwise possible. This technique could be implemented for routine surface hygiene monitoring for targeted cleaning interventions and as a tool to investigate routes of patient-patient transmission in the clinical environment.Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.