J Vet Emerg Crit Care (San Antonio) · Aug 2011
Randomized Controlled TrialAssessment of cardiac output measurement in dogs by transpulmonary pulse contour analysis.
- Andre Shih, Herbert W Maisenbacher, Carsten Bandt, Carolina Ricco, James Bailey, Jess Rivera, and Amara Estrada.
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, FL 32610, USA. shih60@ufl.edu
- J Vet Emerg Crit Care (San Antonio). 2011 Aug 1; 21 (4): 321-7.
ObjectiveTo determine if metatarsal artery pressure (COmet) is comparable to femoral artery pressure (COfem) as the input for transpulmonary pulse contour analysis (PiCCO) in anesthetized dogs, using the lithium dilution method (LiDCO) as a standard for cardiac output (CO) measurement.DesignProspective randomized study.SettingUniversity research laboratory.AnimalsTen healthy purpose-bred mixed breed dogs were anesthetized and instrumented to measure direct blood pressure, heart rate, arterial blood gases, and CO.InterventionsThe CO was measured using LiDCO and PiCCO techniques. Animals had their right femoral and left distal metatarsal artery catheterized for proximal (COfem) and distal (COmet) PiCCO analysis, respectively. Measurements were obtained from each animal during low, normal, and high CO states by changing amount of inhalant anesthetics and heart rate. Measurements were converted to CO indexed to body weigh (CI(BW) =CO/kg) for statistical analysis. Agreement was determined using Bland and Altman analysis and concordance correlation coefficients.Measurements And Main ResultsThirty paired measurements were taken. The LiDCO CI(BW) (± SD) was 68.7 ± 30.3, 176.0 ± 53.0, and 211.1 ± 76.5 mL/kg/min during low, normal, and high CO states, respectively. There was a significant effect of CI(BW) state on bias and relative bias with COmet (P<0.001 and P=0.003, respectively). Bias of the COmet method (± SD) was -116.6 (70.5), 20.1(76.4), and 91.3 (92.0) mL/kg/min at low, normal, and high CI(BW), respectively. Bias of the COfem (± SD) was -20.3 (19.0), 8.6 (70.9), and -2.9 (83.0) mL/kg/min at low, normal, and high CI(BW) , respectively. The mean relative bias for COfem was -6.7 ± 44% (limits of agreements: -81.2 to 67.9%).ConclusionCompared with lithium dilution, the pulse contour analysis provides a good estimation of CO, but requires femoral artery catheterization in anesthetized dogs.© Veterinary Emergency and Critical Care Society 2011.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.