-
Arch. Dis. Child. Fetal Neonatal Ed. · Nov 2003
Comparative StudyMotion resistant pulse oximetry in neonates.
- R Sahni, A Gupta, K Ohira-Kist, and T S Rosen.
- Department of Pediatrics, College of Physicians and Surgeons, Columbia University, New York, NY, USA. rs62@columbia.edu
- Arch. Dis. Child. Fetal Neonatal Ed. 2003 Nov 1; 88 (6): F505-8.
BackgroundPulse oximetry is widely used in neonates. However, its reliability is often affected by motion artefact. Clinicians confronted with questionable oxygen saturation (SpO(2)) values often estimate the reliability by correlating heart rate (HR) obtained with the oximeter with that obtained by electrocardiogram.ObjectiveTo compare the effects of motion on SpO(2) and HR measurements made with Masimo signal extraction technology and those made with a Nellcor N-200.DesignContinuous pulse oximetry and HR monitoring were performed in 15 healthy, term infants (mean (SD) birth weight 3408 (458) g) undergoing circumcision, using Masimo and Nellcor pulse oximeters and a standard HR monitor (Hewlett-Packard). Simultaneous minute by minute behavioural activity codes were also assigned. Baseline data were collected for 10 minutes when the infant was quietly asleep and then continued during and after circumcision for a total duration of one hour. The oximeter HR and SpO(2) values were compared and related to HR values obtained by ECG during all three periods. The effect of behavioural activity on SpO(2) and HR was also evaluated.ResultsWhen compared with results obtained with the Nellcor, the mean SpO(2) and HR were higher and the incidence of artefact lower with the Masimo during all three periods. Masimo HR more accurately predicted HR obtained with a standard monitor, with lower residual error. SpO(2) and HR values obtained with the Nellcor were lower and more variable during all behavioural states, especially crying, when excessive motion artefact was most likely.ConclusionsThe data suggest that Masimo signal extraction technology may offer improvement in pulse oximetry performance, particularly in clinical situations in which extreme motion artefacts are likely.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.