- U C Hoppe, M Vanderheyden, H Sievert, M C Brandt, R Tobar, W Wijns, and Y Rozenman.
- Department of Internal Medicine III, University of Cologne, Kerpener Str. 62, Cologne 50937, Germany. uta.hoppe@uni-koeln.de
- Heart. 2009 Jul 1; 95 (13): 1091-7.
ObjectiveTo evaluate the feasibility and safety of home monitoring of chronic heart failure (CHF) patients using acoustic wireless communication with an implant directly measuring pulmonary artery (PA) pressures.DesignThe PAPIRUS (Pulmonary Artery Pressure by Implantable device Responding to Ultrasonic Signal) II trial was a prospective, multicentre phase I study.Patients31 patients with CHF in New York Heart Association class III-IV.InterventionsImplantation of a miniature device in the right pulmonary artery (PA) responding to ultrasonic signal that enables wireless recording of a complete PA pressure curve.Main Outcome MeasuresThe primary end points were rates of serious adverse device- or implantation-related events at 6 months. Secondary end points included accuracy of the measured PA pressure, functionality of the system and evaluation of pressure readings at different postures.ResultsThe two safety end points were met with no serious adverse events related to the device or implantation. Pressure tracings at 6 months were almost identical to those obtained simultaneously by Millar catheter. Variations of PA diastolic pressure were observed in relation to posture (standing 6.4 (SD 3.4) mm Hg lower than supine, p<0.001). A total of 4627 home measurements were successfully performed by 23 patients using a simple-to-operate hand-held home-unit for daily measurements. The median compliance with daily monitoring was 86%.ConclusionsMeeting the prespecified safety objective of this study warrants a randomised trial to fully evaluate the potential of home monitoring by this miniature PA implant in guiding long-term management in CHF.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.