• Anesthesia and analgesia · Oct 1998

    Comparative Study

    A comparison of three modes of ventilation with the use of an adult circle system in an infant lung model.

    • M J Tobin, G W Stevenson, B J Horn, E H Chen, S C Hall, and C J Coté.
    • Department of Anesthesiology, Children's Memorial Hospital and Northwestern University Medical School, Chicago, Illinois 60614, USA.
    • Anesth. Analg. 1998 Oct 1; 87 (4): 766-71.

    UnlabelledWe examined the efficiency of an adult circle system with adult bellows to deliver minute ventilation (VE) to an infant test lung model. A Narkomed 2B system (North American Drager, Telford, PA) using three modes of ventilator setup were used: A = time-cycled, volume-controlled using bellows excursion to control delivered volume; B = time-cycled, pressure-controlled using inspiratory pressure limit adjustment to control delivered volume; C = time-cycled, pressure-controlled using the inspiratory flow adjustment to control delivered volume. VE was measured with two compliances (normal and low) and four endotracheal tube (ETT) sizes (2.5-, 3.0-, 3.5-, and 4.0-mm inner diameter). VE was measured at peak inspiratory pressures (PIP) of 20, 30, 40 or 50 cm H2O while respiratory rate (RR) was held constant at 20 breaths/min. VE was measured as RR was set at 20, 30, 40, or 50 breaths/min while target PIP was held constant at 20 cm H2O. Data were analyzed using the multiple regression technique. With the low compliance model, VE was nearly identical regardless of the ventilator setup. With the normal compliance model, minor differences in VE were observed, especially at the highest RR and PIP. VE was dependent on RR, PIP, and lung compliance. Overall, the ventilator setup resulted in minor changes in VE. Very high PIPs were required to deliver VE to the low compliance model. ETT size did not affect VE when lung compliance was low; however, smaller ETT size was a factor when test lung compliance was normal, decreasing delivered VE at higher PIP and RR. We conclude that with a Narkomed 2B adult circle system VE is dependent on PIP, RR, and lung compliance, but not on mode of ventilator setup.ImplicationsThe results of this laboratory investigation indicate that when an adult circle system is used during infant anesthesia, the ventilation delivered depends primarily on the respiratory rate, peak inspiratory pressure, and the compliance of the lung being ventilated, rather than on the specific mode of ventilator setup.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.