• Eur. J. Pediatr. · Aug 2014

    Accuracy of a disposable compared to a non-disposable infant T-piece resuscitator.

    • Vera B Krabbe, Jeroen J van Vonderen, Charles C Roehr, and Arjan B Te Pas.
    • Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, J6-S, PO Box 9600, 2300 RC, Leiden, The Netherlands.
    • Eur. J. Pediatr. 2014 Aug 1; 173 (8): 1005-9.

    UnlabelledBoth disposable and non-disposable T-piece resuscitator (TPR) devices are used. Accuracy of the disposable and non-disposable infant TPR was compared. Peak inspiratory pressures (PIP) and positive end-expiratory pressures (PEEP) were measured during ventilation of a test lung. Measured PIP ±1 cmH2O and PEEP ±0.5 cmH2O of the desired pressures were considered acceptable. We tested the following: (A) Accuracy of setting pressures using built-in manometers of three disposable TPRs, (B) Minimal and maximal PIP and PEEP levels for the non-disposable and disposable TPR were measured using different gas flow rates, and (C) Accuracy of 25 caregivers setting pressures (PIP 25 cmH2O and PEEP 5 cmH2O). The results of the tests performed were as follows: (A) With pressures set: PIP 20, 25, 30, and 40 cmH2O and PEEP 5-8 cmH2O with 1 cmH2O stepwise increment, measured PIPs and PEEPs were in acceptable range. (B) At gas flow rates 5, 8, 10, and 15 L/min (disposable vs. non-disposable), min-max PIP were 4.0-43.2 vs. 2.9-77.1 cmH2O and min-max PEEP were 0.3-22.3 and 0.6-59.7 cmH2O. (C) Set PIP (cmH2O) by participants using disposable vs. non-disposable TPR was 25.8 (0.8) vs. 25.9 (1.3) (ns). PEEP was 5.4(0.5) vs. 4.7(0.5); p < 0.001.ConclusionThe accuracy of the disposable TPR is comparable to that of the non-disposable TPR.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.